1. Activate internal heating circuit module if needed
(arrangement/heat. circuit/Options/hc)
2. Adjust parameters for internal heating circuit module
(Arrangement/heat. circuit/hc/...)
3. Activate external heating circuit module(s) if needed
(arrangement/heat. circuit/Option/HC1 (2,3) module)
4. Adjust parameters for external heating circuit module(s)
(arrangement/heat. circuits/Hc1 (2,3) Module/...)
5. Activate desired functions with relay allocation (if needed)
Bypass
(Solar/Options/Bypass)
External heat exchanger
(Solar/Options/Ext. heat. ex)
Cooling function
(Solar/Options/cool. func.)
Parallel relay
(Solar/Options/Par.Relay)
After-heating suppression
(Solar/Options /ah suppress.)
HSE
(arrangement/Options/hse)
Store loading
(arrangement/Options /store load.)
Error message
(Expert/message rel.)
6. Activate further functions without relay allocation (if
needed):
Tube collector function
(Solar/Options/tube col.)
Collector cooling function
(Solar/Options/col. cooling)
Recooling function
(Solar/Options/Recooling)
Frost protection
(Solar/Options/frost. prot.)
Target temperature
(Solar/Options/target tem.)
CS-Bypass
(Solar/Options/CS-Bypass)
3.3 Adjusting the controller step-by-step
The following points are optional to suit the system requirements, points 16. and 17. should be adjusted before the
system is handed over to the operator.
7. Adjust special parameters of the selected options
(Solar/adj. values/...),
(Solar/Expert/...) and
(Arrangement/adj. values/...)
8. Activate functions of function blocks (if needed)
(arrangement/Options/...)
9. Adjust switching conditions for the activated functions
(Arrangement/adj. values/...)
10. Activate heat measurement function (if needed)
(WMZ/Options/...)
11. Adjust special parameters
(WMZ/WMZ 1/Expert/...)
12. Deactivate warning message (if needed)
(Expert/...)
13. Carry out sensor offset (if needed)
(Expert/Sensors/...)
14. Increase minimum speed (if needed)
(Expert/Relay/...)
15. Setup and adjust chimney sweeper function (if needed)
(Expert/chimney/...)
16. Carry out relay test
(manual operation/...)
17. Save adjustments
(user code/0000)