Up to 3 additional external heating circuit modules (HKM)
can be activated if further compensated heating circuits are
required.
Heating circuit module
Arrangement/Heat. circuit/Options/Hc1(2,3)Module
selection: “Yes“, “No“
factory setting: “No“
Arrangement/Heat. circuit/hc/Expert/Sen. outdoor
adjustment range: 1 17
factory setting: 7
change to: 13
The displays and functions are comparable to those of the
internal heating circuit (see also manual „RESOL HKM3“).
Arrangement/heat. circuit/Hc-Module/...
External heating module:
If the external heating circuit module HKM3 is additionally
used, only 1 outdoor temperature sensor is required.
In order to ensure that all heating circuits control using the
same outdoor temperature, adjust to sensor 13 and con-
nect the external sensor to the HKM module.
This function switches off the heating circuit when domes-
tic hot water is being afterheated.
For this purpose, the option domestic hot water priority
and afterheating via store loading (see 4.2) of the controller
DeltaSol
®
E have to be active as well.
Store priority:
Arrangement/heat. circuit/hc1(2,3)module/store
prio.
selection: “On“, “Off“
factory setting: “Off“
This function is used for time- and temperature-controlled
screed drying in selectable heating circuits.
The heating circuits can be selected in the Arrange-
ment / Heat. circuit / HC / Expert menu. At the end of
this menu, the function can be set to standby by using the
„Start“ item.
At the beginning of the screed drying function, the select-
ed heating circuits are put into operation for the adjusted
rise time with the start temperature as the set ow tem-
perature. Afterwards, the set ow temperature increases
in steps by the adjustable rise value for the duration of
the adjustable rise time until the holding temperature is
reached. After the holding time has elapsed, the set ow
temperature is reduced in steps until the start temperature
is reached again.
Note:
Make sure the heating circuits are supplied with heat from
a heat source (afterheating).
Screed drying option
Screed heat
Selection: „Yes“, „No”
Factory setting: „No”
TStart
Adjustment range: 10.0 ... 59.0 °C
Factory setting: 20.0 °C
Tmax
Adjustment range: 11.0 ... 60.0 °C
Factory setting: 40.0 °C
Rise
Adjustment range: 1.0 10.0 K
Factory setting: 2.0 K
Rise time
Adjustment range: 1 ... 72 h
Factory setting: 24 h
tBacking
Adjustment range: 1 ... 20 d
Factory setting: 5 d
Start
Selection: „Yes“, „No”
Factory setting: „No”

Other manuals for Resol DeltaSol E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Resol DeltaSol E and is the answer not in the manual?

Resol DeltaSol E Specifications

General IconGeneral
BrandResol
ModelDeltaSol E
CategoryController
LanguageEnglish

Related product manuals