Preparing the Recorder for
Use
41
The
powerline plug
is inserted in
socket
42
during transport.
Before
connecting to the mains, check the correct
settlng of the voltage
switch
(set
to 22OY by the factory).
In order to
seJ.ect
another voltage,
press
fuse holder 41
by means of a
coin and turn to the correct
posltion.
If turned clockwise to the end, the
fuse may be changed.
Check if the correct
fuse
is in the fuseholder.
Use a miniature
fuse
5
x 20mm
(slow-blow)
:
0.6 A for 220/240V
1.2
A
for 1I0-145
V
ATTENTION
The recorder may be used only for
50 cps AC current. For
60
cps AC
use a converslon
klt,
avallable
from
the manufacturer.
UsA
/
60
cps
In order
to
change the fuse,
press
fuse
holder 41
turn clockwise
to the end.
Use a
miniature
fuse
(slow-blow):
Type 3 AG
by means
of a coin and
1.2 A for 110
-
145 V
ATTENTlON
The recorder may
be used only for
60cps, I17 V AC current.