9 SPECIFICATIONS
Model
GENERAL APD20D APD22D APD70D APD72D
OutputFlow,Minimum,Nlm(SCFM) 5.65(0.2) 4.8(0.17) 19.8(0.7) 16.4(0.58)
MaxSystemVolume,liters(ft
3
),@34.5kPa(5psig) 3500(123)
1
3000(106)
1
16500(582)
1
13500(477)
1
OutputDewPoint,Minimum,Celsius(Fahrenheit)
Ambientdewpoints<=10°(50°):‐40°(40°)dewpoint
Ambientdewpoints>10°(50°):50°(72°)dewpointreduction
OperationalPressure,psig(kPa) Firmwareconfigurablefrom110(6.968.9)
PressureDeadband,psig(kPa) Firmwareconfigurablefrom29(13.862.1)
AmbientOperationalTemperatureRange 040°C(32104°F)
2
AmbientOperationalHumidityRange 585%relative,noncondensing(maximumabsolutehumidity=25g/m
3
)
2
OperationalNoise,dBA@1meter,Standby 0
OperationalNoise,dBA@1meter,Active 60 66
OutputPressureSafetyRelief Fixedat15psig(103.4kPa)
OutputFittingType QuickConnect,3/8"ODPlasticTube
3
MaximumContinuousOperation,Active 4Hours
ELECTRICAL
OperatingVoltage,AC 120V+/10% 230V+/10%
4
120V+/10% 230V+/10%
4
SourceFrequency,Hz,Nominal(Range) 60Hz(4763Hz) 50Hz(4763Hz) 60Hz(4763Hz) 50Hz(4763Hz)
Max.StandbyCurrent,Amps
0.5
Max.ActiveCurrent,Amps 3 2 5 4
Max.ActivePowerConsumption,Watts 320 280 500 420
Max.ActivePowerConsumption,VoltAmps 380 290 520 440
PowerFactorCorrection,typical 0.8
ElectricalFeedCircuitConfiguration SinglePhase,3Conductor(Phase/Neutral/Ground)
4
ElectricalFeedCircuitSizeRecommendation 15Amps
5
ElectricalInletConnector IEC320TypeC14
ALARMS
AlarmConfiguration 1FormCrelaycontacts,screwterminalconnector
AlarmContactRating,Maximum
30VDC,1A
LowPressureAlarm(Standardonallunits)
Standardconfigurations:Fixedat0.5psi(3.4kPa)belowloweroperationalpressure
LowPressureconfigurations:Fixedat0.25psig(1.7kPa)
SIZEANDWEIGHT
Dimensions,HxWxD,inches(mm) 9.5x13.5x9.5(242x343x242)
NetWeight,pounds(kilograms) 25(11.4) 30(13.6)
ENVIRONMENTAL
Max.OperationalAltitude@5psig,feet(meters) 6,500(1,930) 6,000(1,830) 12,400(3,780) 11,500(3,500)
Max.OperationalAltitude@10psig,feet(meters) 5,000(1,525) 4,500(1,370) 10,900(3,325) 9,500(2,900)
Deratingper1000ft(305m)aboveMSL,CFM(lm) 0.024(0.68) 0.022(0.62) 0.07(1.98) 0.06(1.70)
Options:(FieldConfigurable)
LowPressureOperation Softwareconfigurablefrom12.5psig(6.913.8kPa)in0.5psig(3.4kPa)increments
6
HighPressureAlarm Softwareconfigurablefrom311psig(20.775.9kPa)in1psig(6.9kPa)increments
HumidityAlarm Softwareconfigurablefrom2050%RHin10%RHincrements
RunTimeAlarm Softwareconfigurablefrom10minutesto4hoursin10minuteincrements
SystemPurge Softwareconfigurablefrom210daysin2dayincrements
Compliance
CE(EMC,MD,PED,RoHS)
IEC60529IP20
NOTES:
1) Allspecificationsat23°C(73F)and50%RelativeHumidityatmeansealevel(MSL)unlessotherwisenoted.
2) Forindooruseonly.IEC6072133Class3k3(temperaturecontrolledenclosedlocations,humiditynotcontrolled),
Humidity:25g/m3AbsoluteHumidity@85%RH=29.4°C,40°C@25g/m3AbsoluteHumidity=48.8%RH.
3) Tubingusedmustbepolyurethane(durometer95A),polyethylene(durometer44D),ornylon(durometer50D).
4) VoltagesourceperIEC60038(1/N/PE)***NotforusewithNorthAmerican240VACservice***
5) Electricalsupplycircuitmustremainwithinoperatingvoltage specificationsatalltimes.
6) Lower
OperationalPressurefixedat0.5psig(3.4kPa),LowPressurealarmfixedat0.25psig(1.7kPa).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RFS APD-D Series and is the answer not in the manual?

RFS APD-D Series Specifications

General IconGeneral
BrandRFS
ModelAPD-D Series
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals