2.4. Sensitivity influenced by enabled protocols
All protocols can be enabled in the Pro firmware versions; however it is still preferred to enable
only the protocols used for receive.
The sensitivity of the receiver part is highly influenced by the number of protocols enabled in
Type1, Type2, Ext or Ext2 firmware. Lesser protocols enabled will make the receiver more
sensitive for the enabled protocols.
There are a few protocols that will reduce or even eliminate receiving of other protocols if
enabled in Type1, Type2, Ext or Ext2 firmware.
For example:
If the AD (LightwaveRF, Siemens) protocol is enabled it can stop receiving of Meiantech /
Atlantic, Oregon 3.0,Visonic and Mertik.
All other protocols are disabled if BlindsT0 is enabled in Type1, Type2, Ext or Ext2 firmware.
Green = enabled by default