SYSTEM ASSEMBLY
52
Solar cold pipe: Connect the solar cold pipe
to the union on the left hand end of the solar
storage tank and collector simultaneously.
Ensure the pipe is parallel with the collector.
Push the pipe against the tank union stop and
hand tighten the gland nut. Hand tighten the
gland nut at the collector. Fully tighten both
ends of the solar cold pipe.
Solar hot pipe: Connect the solar hot pipe to the fitted union body on the right hand end of the solar
storage tank and collector simultaneously. Push pipe against the tank union stop and hand tighten the
gland nut. Ensure the pipe is parallel with the collector. Hand tighten the gland nut at the collector.
Fully tighten both ends of the solar hot pipe.
52H indirect system: The union body R 3/4 M x
G 3/4 M to tank socket is not required for the
indirect system. Fit an adaptor union M33 M x
G3/4 F and O’ring, one into collector cold inlet
at the bottom left hand side of the first collector
and another into the hot outlet at the top right
hand side of the second or third collector.
Solar cold pipe: Connect the solar cold pipe
to the heat exchanger connection on the left
hand end of the solar storage tank and
collector simultaneously. Ensure the pipe is
parallel with the collector. Push the pipe
against the tank socket sealing face and
hand tighten the gland nut. Hand tighten the
gland nut at the collector. Fully tighten both
ends of the solar cold pipe.
Solar hot pipe: Connect the solar hot pipe to
the heat exchanger connection on the right
hand end of the solar storage tank and
collector simultaneously. Ensure the pipe is
parallel with the collector. Push the pipe
against the tank socket sealing face and
hand tighten the gland nut. Hand tighten the
gland nut at the collector. Fully tighten both
ends of the solar hot pipe.
After connecting the tank to collector pipe work,
tighten the nuts on the clamps at the collector
rail to secure the solar collectors.
14. Fill Drain Valve (Indirect System Only):
52H indirect system: Fit an adaptor union M33 M x
G3/4 F and O’ring to the collector connection prior to
connecting the fill drain valve assembly to the collector
at the collector connection. Fit the fill drain valve
assembly to the bottom right connection of the solar
collectors.
15. Fill / Drain Label: 52H indirect system: Attach the
Fill / Drain label to the side of the solar collector
adjacent to the fill drain valve assembly.
0-RING
COPPER
BLANKING DISC
M33 GLAND NUT
3/4" GLAND NUT
COLLECTOR
BUNG
O-RING
ADAPTOR M33 to 3/4 CONE
SOLAR PIPE WITH
CONETITE FITTINGS
SOLAR PIPE WITH
CONETITE FITTINGS
O-RING
O-RING
M33 COLLECTOR
CONNECTOR
ASSEMBLY
CONETITE COLLECTOR
CONNECTOR ASSEMBLY
0-RING
ADAPTOR M33 to
3/4 CONE
FILL/DRAIN FITTING ASSEMBLY
conetite fill/drain fitting, 3/4" gland
nut, plug
Solar Pipe Connection
Collector Connection Detail
Collector Inter-Connection
Collector Fill/Drain Fitting
Collector Connection Blanking
J COLLECTORS
NPT200 COLLECTORS
J COLLECTORS
NPT200 COLLECTORS
J COLLECTORS
NPT200 COLLECTORS
J COLLECTORS
NPT200 COLLECTORS
FILL/DRAIN FITTING ASSEMBLY
conetite fill/drain fitting, 3/4" gland
nut, plug
connection details - solar hiline CC 52C S200 NPT200 - SK7548- 4 rev BD.doc
14/03/2014
Thermosiphon 52C Series Hiline
hot pipe
cold pipe
male gland nut
heat exchanger tank socket
(indirect system)
solar cold/
hot pipe
tank & collector pipe connection (indirect system)