HEAT PUMP AND TANK ASSEMBLY
13
5. Lifting Bars: Insert the two (2) lifting bars into the slots at the front of the
heat pump module chassis and carefully push through to engage the slots
at the rear.
Take care not to catch any of the wiring or hoses in the heat pump
module.
Leave sufficient overhang at either end to enable a firm and safe grip for
lifting the heat pump module onto the top of the storage tank.
Steps 3 and 5
remove louvres and insert lifting bars into the slots provided