TM063 701, 702 & 703 Series Boiling Water Unit Service Instructions
Revision D: Feb 2017
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Fault Finding Tests 9
Test 9
Using a multimeter on the ohms scale,
measure between the orange and yellow
wires. When the button is pressed the
following result should be obtained:
10 13 ohms.
(Note:- Eco timer ribbon wiring must be
connected to do this test)