EasyManua.ls Logo

Rheem 70103 User Manual

Rheem 70103
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TM063 701, 702 & 703 Series Boiling Water Unit Service Instructions 1
Revision D: Feb 2017
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
70103
70303
70207
70105
70305
70210
70307
70215
70225
70240
Revision D
Published: 02/2017
701
702
703
Question and Answer IconNeed help?

Do you have a question about the Rheem 70103 and is the answer not in the manual?

Rheem 70103 Specifications

General IconGeneral
BrandRheem
Model70103
CategoryBoiler
LanguageEnglish

Summary

Safety Warning

Preventative Maintenance

Operation

Operational Flow Charts

Operational Flow Chart – 703 Series

Activating Calibration Reset Mode

Activating Temp Override

Activate calibration reset mode (NZ Pre-2014 Models)

Activate calibration reset mode (Standard)

Components and their Function

Fault Finding

Error Codes (701 & 702 Series Only)

Error Codes (703 Series only)

Testing the Boiling Water Thermistor

Fault Finding Charts, Fault Diagnosis Sequence

Thermistor and Triac Faults

Error Codes A-D

Troubleshooting for thermistor, triac, and probe issues.

Timer and Calibration Faults

Error Codes E, G

Troubleshooting for filter and calibration time-out errors.

Probe Fault Diagnostics

Error Codes H, J

Troubleshooting for low and high level probe faults.

Heating and Temperature Faults

Error Codes K, L, N

Troubleshooting for heating, ECO, and temperature rise errors.

Fault Finding Chart 1

Fault Finding Chart 1.1

Fault Finding Chart 1.1a

Fault Finding Chart 2

Fault Finding Chart 3

Fault Finding Chart 4, 4.1 & 4.2

Fault Finding Chart 4a, incl. (4.1 & 4.2) 703 Series

Fault Finding Chart 5

Fault Finding Chart 5a 703 series

Fault Finding Chart 6

Fault Finding Chart 7

Fault Finding Tests

Fault Finding Tests 3B – 6A

Fault Finding Tests 6A – 8

Fault Finding Tests 9

Electrical Safety Testing

Component Replacement Procedures

Tap (Procedure 2B) 701 Tap, timer fascia replacement

Tap components (Procedure 3A) 702 & 703 Series

Inlet Strainer (Procedure 5) all models

Inlet Solenoid Valve & Inlet Fitting (Procedure 6)

Element (Procedure 10)

Boiling Water E.C.O. (Procedure 11)

Boiling Water Thermistor (Procedure 12)

Level Probe (Procedure 13)

Control Board (Procedure 14)

Water Outlet Flange (Procedure 16A) 702 & 703 Series

Water Outlet Flange (Procedure 16B) 701 Series

Boiling Water Storage Tank & Tank Insulation All models (Procedure 17)

Related product manuals