6 Rheem Heating, Cooling and Water Heating
RXPF-F01 and F02
FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and Classic
Series warm air furnaces. RXPF-F02 meets TVA requirements.
ACCESSORIES—DOWNFLOW
DOWNFLOW WARNING: Unit design is certified for installation on non-com-
bustible floor. A special factory supplied combustible floor sub-base is
required when installing on a combustible floor. Failure to install the sub-base
may result in fire, property damage and personal injury.
COMBUSTIBLE
FLOOR BASE
A
IN. [mm]
B
IN. [mm]
USE WITH
FURNACE SIZES
RXGC-B24
25 [635] 23
3
/4 [603]
RGLQ-12, RGLQ-15
RXGC-B14
14
1
/2 [368] 13
1
/4 [337]
RGLQ-05
RXGC-B17 18 [457] 16
3
/4 [425]RGLQ-07, RGLQ-10(-)A
RXGC-B21 21
1
/2 [546] 20
1
/4 [514]RGLQ-10(-)B
C
IN. [mm]
21
3
/4 [552]
11
1
/4 [286]
14
3
/4 [451]
18
1
/4 [464]
FOR HIGH ALTITUDES:
HIGH ALTITUDE CONVERSION:
See Installation Instructions for more high altitude information.
CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines
when converting furnaces for high altitudes.
COMBUSTIBLE FLOOR BASE DIMENSIONS
RXGF-CC*
FILTER RACK—Downflow top
return mount.
NOTE: Filter racks are shipped
without filters.
*Filters available through PROSTOCK
®
.
14
1
/2 [356] 45 [13.19] & 50 [14.65] 14 [356] x 20 [508] 1
17
1
/2 [445] 67 [19.64], 75 [21.98] & 100 [29.31] 12 [305] x 20 [508] 1
21
1
/2 [533] 100 [29.31] 12 [305] x 20 [508] 2
24
1
/2 [622] 125 [36.63] & 150 [44.0] 14 [356] x 20 [508] 2
DOWNFLOW FILTER SIZES
FURNACE
WIDTH
IN. [mm]
INPUT
BTUH [kW]
SIZE
IN. [mm]
QUANTITY
[ ] Designates Metric Conversions