TRITON
80 & 100 Gallon Ultra-High
Efficiency Water Heaters
Service and Training Manual
For use with the following models:
GHE80SS, GHE80SU,
GHE100SS, GHE100SU
CATEGORY IV Models
Fan Assisted Combustion
SVC1020T; Revision 4; January 2020

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem GHE119-500 and is the answer not in the manual?

Rheem GHE119-500 Specifications

General IconGeneral
BrandRheem
ModelGHE119-500
CategoryWater Heater
LanguageEnglish

Summary

Introduction to Rheem Triton Water Heaters

Safety Precautions and Warnings

General safety precautions and warnings for operating the water heater.

User Interface Overview

TRITON User Interface Settings

TRITON User Interface Menus

TRITON User Interface Alarms and Health

Alarm Monitoring and History

View current alarms, get more info, and access alarm history.

Troubleshooting Specific Alarms

Provides guidance for specific alarms and troubleshooting steps.

Safety Functions of the Controls

Additional Safety Functions

Error Codes List

TRITON Error Codes

TRITON Error Codes List

TRITON Error Codes Reference

Troubleshooting Error Codes

Error A001 Ignition Lockout

Unit locks out after 27 failed ignition cycles; troubleshooting steps provided.

Troubleshooting Error Codes (Continued)

Troubleshooting Error Codes: Flame and Intake

Error A002 Flame is Not Stable

Flame rectification signal lost three times in one heating cycle; check gas pressure, vents, rod.

Error A003 Intake Switch Open

Intake pressure switch opens due to blockage in intake venting; check wiring and tubing.

Troubleshooting Error Codes: PoF Switch

Error A004 PoF Open During Heating

Proof of Fan switch is open during heating; check wiring, tubing, and air intake.

Error A005 PoF Open During Pre-Purge

Proof of Fan switch is open during pre-purge; check wiring, tubing, and blower operation.

Error A006 PoF Open During Post Purge

Proof of Fan switch is open during post-purge; check wiring, tubing, and air intake.

Troubleshooting Error Codes: Exhaust & Mismatch

Error A007 Exhaust Pressure Switch Open

Exhaust pressure switch opens due to excess pressure in exhaust venting.

Error A008 PoF;Blower Mismatch

Proof of Fan switch is closed when blower is off; check blower operation and switch continuity.

Error A016 Energy Cut Off Switch Is Open

Tank temperature exceeded allowable temp; check probe, wiring, and ECO switch.

Troubleshooting Error Codes: Flue Temperature

Error A017 Flue High Flue Temp

Combustion gases are too hot at exhaust tee; check wires, elbow, Molex, and sensor readings.

Troubleshooting Error Codes: Flue Sensor Issues

Error A018 Flue Temp Sensor Open

Control senses flue temperature sensor is open or disconnected. Refer to A017.

Error A019 Flue Temp Sensor Shorted

Control senses a short in the flue temperature sensor or wiring harness. Refer to A017.

Error A022 Upper Tank Sensor is Open

Water temperature probe not connected or thermistor damaged; check Molex, wiring, and resistance.

Troubleshooting Error Codes: Upper Tank & Blower

Error A023 Upper Tank Temp Too Hot

Upper tank temperature exceeded 205°F; check probe, wiring, or ignition board.

Error A024 Upper Tank Sensor Shorted

Short detected in ECO/temperature probe or wiring. Refer to A022.

Error A025 No Blower RPM Feedback

Control does not detect blower RPM; check blower voltage, wiring, or blower itself.

Error A026 Blower RPM Mismatch

Blower RPM mismatch detected; check wiring harness and potentially replace blower.

Error A027 Flame Present Before Ignition

Flame detected prior to ignition; check for flame, earth ground, or replace controller.

Troubleshooting Error Codes: Flame & Communication

Error A028 Flame Present W;O Heating

Flame signal detected after heating cycle closed; check flame, gas valve, or flame rod.

Error A029 Failed Ignition

Unit fails ignition 9 times, gives A029. Refer to A001 for troubleshooting.

Error A030 Flame Lost During Heating

Unit lost flame signal during heating; attempts 3 times, then locks out with A002.

Troubleshooting Error Codes: Configuration & Leaks

Error A104 Water Leak Detected

Water leak detected by control; check for leaks, sensor, or resolve leak.

Troubleshooting Error Codes: Valve & Sensors

Error A121 No Water Detected in Tank

No water detected; ensure tank is full, check for anode alerts, and follow diagnostic steps.

Error T009 No Gas Detected

Gas pressure switch is open; check wiring, inlet gas pressure, or replace switch.

Error T020 Lower Tank Sensor Open

Lower tank temperature sensor is open; check harness, resistance, or replace sensor/board.

Error T021 Lower Tank Sensor Shorted

Short detected in lower temperature probe wiring; check probe, wiring, or board.

Troubleshooting Error Codes: Ignition & Maintenance

Error T029 Failed Ignition. Retrying

Unit fails ignition 9 times, gives A029. Refer to A001 for troubleshooting.

Troubleshooting Error Codes: Anode Communication

Gas Pressure Checking Procedures

Gas Valve Adjustment Procedure

BACnet Configurations Guide

BACnet Configurations Details

BACnet Configurations Input

BACnet Configurations Settings

BACnet Quick Start Guide

Leak Guard System Information