Fault Code Meaning of Code
OFF The desired programmed temperature point is lower than 60°F (15°C).
L
P & LP3
Shortage of refrigerant gas in the unit or faulty low pressure control. The unit will show
(
LP3) after 3 LP faults and shuts down the unit and pool pump for protection. If this occurs,
you should call for service.
HP & HP3
Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The
unit will show (HP3) after 3 HP faults. This will stop the unit for protection.
FLo & FL3
Possible causes:
The filter is in backwash position.
The filter pump is stopped.
The filter is dirty.
Shortage of water to pool pump.
FIL parameter must be set to activate pool pump.
Water pressure switch must be adjusted or it is broken.
The unit is in the protection mode and will show (FL3), press any key to restart the unit.
FL3 code will stop the unit and pool pump.
FS
Unit is in the defrosting cycle.
(The fan works but the compressor is stopped.)
- - Keypad is pressing down on both buttons. Replace keypad.
Table C: Control Board Fault Codes Digital Models

Other manuals for Rheem M8350ti-E-HC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem M8350ti-E-HC and is the answer not in the manual?

Rheem M8350ti-E-HC Specifications

General IconGeneral
BrandRheem
ModelM8350ti-E-HC
CategorySwimming Pool Heater
LanguageEnglish

Related product manuals