INSTALLATION
Active Compressor Protection Mode
EcoNet Enabled 2-Stage Control™
Clear Fault History (UP and SELECT Buttons)
s#LEAR&!5,4()34/29BYPRESSINGBOTH50AND
3%,%#4BUTTONFORlVESECONDSWITHINSULATED
probes and release.
s4HETOPANDBOTTOMSEGMENTSOFTHEDUALSEGMENT
LEDs flash to indicate the history has been cleared.
NOTE: The memory card for the system has
specific model data for this system. The memory card
is attached to the control box with a tether. The tether
has an identification tag that can be used to identify the
memory card. For the system data fault D1 reference the
label on the memory card tether.
The series of heat pumps allow the installer to use
conventional 24VAC control wiring and a conventional
thermostat for proper unit operation.
)-0/24!.4The preferred method of unit installation and
operation is with the EcoNet Communication System™.
The EcoNet Communication System™ allows access to the