EasyManua.ls Logo

Rheem RANL-JAZ - Model Number Configurations (Page 20)

Rheem RANL-JAZ
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Air
Performance Data
RAPM- JAZ Series
20
Model Numbers
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Sound
Rating
dB
Indoor
CFM [L/s]
Outdoor
Unit
RAPM-
Indoor
Coil and/or
Air Handler
Total
Capacity
BTU/H [kW]
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
EER SEER
036JAZ
RCQD-3621(ROCA-070E03) 37,400 [11.0] 26,750 [7.8] 10,650 [3.1] 12.00 14.50 76 1,200 [566]
RCQD-3621(ROCA-070E04) 37,400 [11.0] 26,750 [7.8] 10,650 [3.1] 12.00 14.50 76 1,200 [566]
RCQD-3621(ROLA-070E03) 37,400 [11.0] 26,550 [7.8] 10,850 [3.2] 12.50 15.10 76 1,175 [554]
RCQD-3621(ROLA-070E04) 37,400 [11.0] 26,550 [7.8] 10,850 [3.2] 12.50 15.10 76 1,175 [554]
RCQD-3621(ROLA-115E05) 36,800 [10.8] 25,350 [7.4] 11,450 [3.4] 13.00 15.50 76 1,050 [495]
RCQD-3621+RXMD-C04 36,200 [10.6] 24,950 [7.3] 11,250 [3.3] 11.50 14.00 76 1,045 [493]
RCQD-3624(RGFE-09?ZCM?) 37,400 [11.0] 26,700 [7.8] 10,700 [3.1] 12.50 15.10 76 1,200 [566]
RCQD-3624(RGFG-09?ZCM?) 37,600 [11.0] 26,850 [7.9] 10,750 [3.1] 12.50 15.10 76 1,200 [566]
RCQD-3624(RGFG-10?ZCM?) 37,000 [10.8] 25,550 [7.5] 11,450 [3.4] 13.00 15.50 76 1,050 [495]
RCQD-3624(RGJF-10?ZCM?) 37,400 [11.0] 26,700 [7.8] 10,700 [3.1] 12.50 15.10 76 1,200 [566]
RCQD-3624(RGJF-12?RCM?) 37,600 [11.0] 26,850 [7.9] 10,750 [3.1] 13.00 15.50 76 1,200 [566]
RCQD-3624(RGPE-07?BRQ?) 36,800 [10.8] 25,350 [7.4] 11,450 [3.4] 13.00 15.50 76 1,050 [495]
RCQD-3624(RGPE-10?BRM?) 37,000 [10.8] 25,650 [7.5] 11,350 [3.3] 13.00 15.50 76 1,075 [507]
RCQD-3624(RGPE-12?ARM?) 37,200 [10.9] 25,850 [7.6] 11,350 [3.3] 13.00 15.50 76 1,075 [507]
RCQD-3624(RGPT-07?BRQ?) 37,000 [10.8] 25,500 [7.5] 11,500 [3.4] 13.00 15.50 76 1,050 [495]
RCQD-3624(RGPT-10?BRM?) 37,200 [10.9] 25,850 [7.6] 11,350 [3.3] 13.00 15.50 76 1,075 [507]
RCQD-3624(RGRM-07?YBG?) 36,400 [10.7] 25,050 [7.3] 11,350 [3.3] 12.00 14.50 76 1,050 [495]
RCQD-3624(RGRM-09?ZAJ?) 36,800 [10.8] 25,550 [7.5] 11,250 [3.3] 12.50 15.10 76 1,075 [507]
RCQD-3624(RGRM-10?ZAJ?) 38,000 [11.1] 27,800 [8.1] 10,200 [3.0] 12.50 15.10 76 1,150 [543]
RCQD-3624(RGRM-12?RAJ?) 37,000 [10.8] 25,700 [7.5] 11,300 [3.3] 13.00 15.50 76 1,075 [507]
RCQD-3624(ROCA-070E03) 37,400 [11.0] 26,750 [7.8] 10,650 [3.1] 12.50 15.00 76 1,200 [566]
RCQD-3624(ROCA-070E04) 37,400 [11.0] 26,750 [7.8] 10,650 [3.1] 12.50 15.00 76 1,200 [566]
RCQD-3624(ROLA-070E03) 37,400 [11.0] 26,550 [7.8] 10,850 [3.2] 12.50 15.10 76 1,175 [554]
RCQD-3624(ROLA-070E04) 37,400 [11.0] 26,550 [7.8] 10,850 [3.2] 12.50 15.10 76 1,175 [554]
RCQD-3624(ROLA-115E05) 36,800 [10.8] 25,350 [7.4] 11,450 [3.4] 13.00 15.50 76 1,050 [495]
RCQD-3624+RXMD-C04 36,200 [10.6] 24,950 [7.3] 11,250 [3.3] 11.50 14.00 76 1,045 [493]
RHKL-HM3617(RCSL-H*3617) 36,000 [10.5] 24,200 [7.1] 11,800 [3.5] 13.00 15.50 76 1,025 [484]
RHLL-HM3617(RCSL-H*3617) 35,800 [10.5] 23,800 [7.0] 12,000 [3.5] 13.00 15.50 76 1,000 [472]
RHSL-HM3617(RCSL-H*3617) 35,600 [10.4] 24,200 [7.1] 11,400 [3.3] 12.00 14.50 76 1,100 [519]
RHSL-HM3621(RCSL-H*3621) 35,600 [10.4] 24,200 [7.1] 11,400 [3.3] 12.00 14.50 76 1,100 [519]
RHKL-HM3821(RCSL-H*3821) 38,000 [11.1] 26,900 [7.9] 11,100 [3.3] 13.00 16.00 76 1,200 [566]
RHLL-HM3821(RCSL-H*3821) 37,800 [11.1] 26,600 [7.8] 11,200 [3.3] 13.00 16.00 76 1,175 [554]
RHPN-HM3624(RCSN-H*3624) 40,000 [11.7] 29,450 [8.6] 10,550 [3.1] 13.00 16.00 76 1,200 [566]
042JAZ
RCFL-H*4821+RXMD-C04
39,500 [11.6] 27,500 [8.1] 12,000 [3.5] 12.00 14.50 76 1,250 [590]
RCFL-A*3821(RGLT-07?AMK?) 40,000 [11.7] 27,900 [8.2] 12,100 [3.5] 12.50 15.10 76 1,250 [590]
RCFL-A*3821(RGLT-07?BRQ?) 40,000 [11.7] 27,800 [8.1] 12,200 [3.6] 13.00 15.50 76 1,250 [590]
RCFL-A*3821(RGLT-10?BRM?) 40,000 [11.7] 27,800 [8.1] 12,200 [3.6] 13.00 15.50 76 1,250 [590]
RCFL-A*3821(RGPE-07?AMK?) 40,500 [11.9] 27,900 [8.2] 12,600 [3.7] 12.50 15.10 76 1,225 [578]
RCFL-A*3821(RGPT-05?BMK?) 39,500 [11.6] 27,450 [8.0] 12,050 [3.5] 12.00 14.50 76 1,225 [578]
RCFL-A*3821(RGPT-07?AMK?) 39,500 [11.6] 27,450 [8.0] 12,050 [3.5] 12.00 14.50 76 1,250 [590]
RCFL-A*3821(RGPT-07?BRQ?) 40,000 [11.7] 27,800 [8.1] 12,200 [3.6] 13.00 15.50 76 1,250 [590]
RCFL-A*3821(RGPT-10?BRM?) 40,000 [11.7] 27,800 [8.1] 12,200 [3.6] 13.00 15.50 76 1,225 [578]
RCFL-A*3821(ROCA-070E03) 39,500 [11.6] 27,150 [8.0] 12,350 [3.6] 12.50 15.10 76 1,200 [566]
RCFL-A*3821(ROCA-070E04) 39,500 [11.6] 27,150 [8.0] 12,350 [3.6] 12.50 15.10 76 1,200 [566]
RCFL-A*3821(ROLA-070E03) 39,500 [11.6] 26,950 [7.9] 12,550 [3.7] 12.50 15.50 76 1,175 [554]
RCFL-A*3821(ROLA-070E04) 39,500 [11.6] 26,950 [7.9] 12,550 [3.7] 12.50 15.50 76 1,175 [554]
RCFL-A*4821(RGFE-09?ZCM?) 39,500 [11.6] 27,150 [8.0] 12,350 [3.6] 12.50 15.10 76 1,200 [566]
RCFL-A*4821(RGFE-10?ZCM?) 40,000 [11.7] 27,900 [8.2] 12,100 [3.5] 12.50 15.10 76 1,225 [578]
Rev.
6/14/12
Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling