EasyManua.ls Logo

Rheem RASL-JEC - Electrical Checks Flow Chart

Rheem RASL-JEC
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
18.3 Electrical Checks Flow Chart
No
No
No
No
Yes
Yes
Yes
Yes
Outdoor Unit
Running?
7-Segment display lit?
Flashing Mode Character
Alternating “C” and “##” (Code)
SEE PANEL COVER OR
OTHER DOCUMENTATION
FOR FAULT CODE
TROUBLESHOOTING.
Control in Lockout Mode.
Check fault history and refer to
Diagnostic Chart.
Note: For solid comm LED, check
comm wiring, term/bus switches at
ICC and AH ctrls.
Refer to panel cover/documentation
for Fault Code Troubleshooting.
Check fault history for other faults.
Check control voltage (R and C)
to control
Waiting for Anti-S.C. Delay to clear
Thermostat call
For cooling, no cooling
No
Yes
Y1 LED lit?
No call received.
24V Systems: Check thermostat,
control wiring
Comm Systems: Check comm.
wiring, T-Stat

Related product manuals