If the information in these instructions is not followed exactly, a
fire or explosion may result, causing property damage, personal
injury or death.
INSTALLATION INSTRUCTIONS
FOR UPFLOW & DOWNFLOW/HORIZONTAL HIGH
EFFICIENCY CONDENSING GAS FURNACES
RGRA/RGRJ AND RGTA/RGTJ SERIES
92-23531-16-09
SUPERSEDES 92-23531-16-08
THESE INSTRUCTIONS ARE
INTENDED AS AN AID TO
QUALIFIED SERVICE
PERSONNEL FOR PROPER
INSTALLATION, ADJUSTMENT
AND OPERATION OF THIS
UNIT. READ THESE
INSTRUCTIONS THOROUGHLY
BEFORE ATTEMPTING
INSTALLATION OR
OPERATION. FAILURE TO
FOLLOW THESE
INSTRUCTIONS MAY RESULT
IN IMPROPER INSTALLATION,
ADJUSTMENT, SERVICE OR
MAINTENANCE, POSSIBLY
RESULTING IN FIRE,
ELECTRICAL SHOCK, CARBON
MONOXIDE POISONING,
EXPLOSION, PROPERTY
DAMAGE, PERSONAL INJURY
OR DEATH.
Do Not Destroy this Manual.
Please read carefully and keep
in a safe place for future
reference by a serviceman.
WARNING
Recognize this symbol as an indication of Important Safety Information!
!
Do not store or use gasoline or other
flammable vapors and liquids, or other
combustible materials in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Do not return to your home until
authorized by the gas supplier or fire
department.
DO NOT RELY ON SMELL ALONE TO
DETECT LEAKS. DUE TO VARIOUS
FACTORS, YOU MAY NOT BE ABLE TO
SMELL FUEL GASES.
U.L. recognized fuel gas and CO
detectors are recommended in all
applications, and their installation should
be in accordance with the manufacturer’s
recommendations and/or local laws,
rules, regulations, or customs
Improper installation, adjustment, alteration,
service or maintenance can cause injury,
property damage or death. Refer to this
manual. Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
WARNING
!
PROPOSITION 65: THIS FURNACE CONTAINS FIBERGLASS
INSULATION. RESPIRABLE PARTICLES OF FIBERGLASS ARE
KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
EXHAUST GAS FROM THIS FURNACE CONTAINS CHEMICALS,
INCLUDING CARBON MONOXIDE, KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER
REPRODUCTIVE HARM.
WARNING
!
FOR YOUR SAFETY
!

Questions and Answers:

Rheem RGTJ series Specifications

General IconGeneral
BrandRheem
ModelRGTJ series
CategoryFurnace
LanguageEnglish

Summary

Safety Precautions

General Furnace Safety Warnings

Critical warnings regarding fire, explosion, and personal injury during furnace operation.

Proposition 65 and Chemical Hazard Alerts

Alerts on fiberglass insulation and exhaust gas components known to cause harm.

Gas Safety and Leak Detection Procedures

Essential safety advice for gas leaks, appliance use, and recommended detectors.

Important Operational Notes

Location Requirements and Site Considerations

Specific Installation Site Requirements

Upflow Unit Combustible Clearances

Downflow Unit Combustible Clearances

Horizontal Unit Combustible Clearances

Ducting Installation and Airflow Management

Ducting Connection and Airflow Procedures

Proper duct connection and airflow for Upflow, Downflow, and Horizontal units.

Venting and Combustion Air Piping Fundamentals

Venting and Air Supply Basics

Condensate formation, safety switches, and existing vent system considerations.

Combustion and Ventilation Air Requirements

Non-Direct Vent Air Supply Needs

Ensuring adequate air for combustion and ventilation in non-direct vent systems.

Vent Pipe Installation Guidelines

Direct Vent Installation Requirements

Direct Vent Safety Warnings and Piping Rules

Safety warnings and installation rules for direct vent piping systems.

Direct Vent Combustion and Exhaust Piping

Horizontal Direct Vent Location Requirements

Furnace Pipe Connections

Condensate Drain and Neutralizer Systems

Upflow Condensate Drain Setup Details

Condensate trap location and drain connection for upflow units.

Downflow Condensate Drain Setup Details

Condensate trap location and drain connection for downflow units.

Gas Supply and Piping Installation

Gas Supply and Conversion Information

Furnace factory set for natural gas; LP conversion kit is required.

Gas Pressure Management and Safety

LP Gas Conversion Procedures

Setting Gas Pressure Parameters

Electrical Wiring and Safety Procedures

Electrical Safety, Grounding, and Switch Precautions

Disconnect power, proper grounding, and blower door safety switch warnings.

Electrical Connection Guidelines

Connecting furnace to electrical supply and disconnect for safe operation.

Thermostat and Low Voltage Wiring

System Operation and Routine Maintenance

Honeywell/UTEC Control Board Wiring Diagram

UTEC/Johnson Controls Spark Ignition Wiring Diagram

UTEC Control Board Wiring Diagram (RGRJ/RGTJ)