EasyManua.ls Logo

Rheem RHLL-HM2417AA User Manual

Rheem RHLL-HM2417AA
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
92-20521-32-15
SUPERSEDES 92-20521-32-14
WARNING
WARNING
!
These instructions are intended as an aid to qualified licensed
service personnel for proper installation, adjustment and
operation of this unit. Read these instructions thoroughly before
attempting installation or operation. Failure to follow these
instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical
shock, property damage, personal injury or death.
ISO 9001:2008
AIR HANDLERS
FEATURING INDUSTRY STANDARD R-410A REFRIGERANT:
RHLL High Efficiency
RHSL Standard Efficiency
INSTALLATION INSTRUCTIONS
refrigerant

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem RHLL-HM2417AA and is the answer not in the manual?

Rheem RHLL-HM2417AA Specifications

General IconGeneral
ModelRHLL-HM2417AA
TypeAir Handler
Airflow1200 CFM
RefrigerantR-410A
Voltage208/230V
Phase1
Motor TypeECM
Cooling Capacity24000 BTU
Depth21 inches

Summary

General Information

Clearances

Specifies required clearances to combustible materials for unit installation.

Applications

Vertical Upflow

Describes the factory configuration and installation for vertical upflow applications.

Vertical Downflow

Details the conversion process from upflow to vertical downflow installation.

Horizontal

Explains how to convert the unit for horizontal airflow configurations.

Electrical Wiring

Power Wiring

Covers requirements for supplying adequate electrical power and branch circuit protection.

Control Wiring

Details low voltage control wiring practices and separation from power wiring.

Grounding

Emphasizes the necessity of permanent grounding for electrical safety.

Electrical Data – With Electric Heat: (-)HSL

Detailed electrical data for HSL models with electric heat.

Electrical Data – With Electric Heat: (-)HLL

Detailed electrical data for HLL models with electric heat.

Heater Kit Supplemental Information

Information regarding the use of standard circuit breakers with approved heater kits.

Airflow Performance

Airflow Operating Limits

Defines the operating limits for airflow based on cabinet size and cooling/heating.

240V Airflow Performance Data – (-)HSL (PSC Motor)

Airflow data for 240V HSL models with PSC motors across static pressures.

115/208/480V Airflow Performance Data – (-)HSL (PSC Motor)

Airflow data for 115/208/480V HSL models with PSC motors.

115/208/240/480V Airflow Performance Data – (-)HLL (X-13 MOTOR)

Airflow data for HLL models with X-13 motors across various voltages and static pressures.

Sequence of Operation

Calculations

Pre-Start Checklist

Maintenance