92-20521-32-15
SUPERSEDES 92-20521-32-14
WARNING
WARNING
!
These instructions are intended as an aid to qualified licensed
service personnel for proper installation, adjustment and
operation of this unit. Read these instructions thoroughly before
attempting installation or operation. Failure to follow these
instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical
shock, property damage, personal injury or death.
ISO 9001:2008
AIR HANDLERS
FEATURING INDUSTRY STANDARD R-410A REFRIGERANT:
RHLL High Efficiency
RHSL Standard Efficiency
INSTALLATION INSTRUCTIONS
refrigerant

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem RHSL-HM1817AA and is the answer not in the manual?

Rheem RHSL-HM1817AA Specifications

General IconGeneral
ModelRHSL-HM1817AA
TypeAir Handler
Airflow600 CFM
RefrigerantR-410A
Energy Efficiency Ratio (EER)12.0
Phase1
Motor TypePSC
Cooling Capacity1.5 Ton
Nominal Cooling Capacity1.5 Ton
Dimensions17-1/2 x 42-1/2 inches
Voltage208/230V
Maximum External Static Pressure0.5 in. wg
Cabinet TypeInsulated
Width17.5 in
Length34.5 in

Summary

Safety Information and Warnings

Electrical Wiring and Connections

Power Wiring Requirements

Details requirements for power supply, wiring, and circuit protection.

Control Wiring Procedures

Explains low-voltage wiring connections for system control.

Unit Grounding Safety

Emphasizes the importance of proper grounding for electrical safety.

Blower Motor Electrical Data (No Heat)

Provides electrical specifications for blower motors without electric heat.

Electric Heat Electrical Data

Details electrical specifications for units with electric heat kits.

Airflow Performance Specifications

Airflow Operating Limits

Specifies minimum and maximum airflow limits for operation.

HSL PSC Motor Airflow (240V)

Airflow performance for 240V HSL PSC motor models.

HSL PSC Motor Airflow (115/208/480V)

Airflow performance for 115/208/480V HSL PSC motor models.

HLL X-13 Motor Airflow (115-480V)

Airflow performance for 115/208/240/480V HLL X-13 motor models.

Ductwork Installation Guidelines

Refrigerant Connections

Air Filter Requirements

Sequence of Operation

Cooling Operation Sequence

Sequence for cooling operation with electric heat or heat pump.

Electric Heat Operation Sequence

Sequence for heating operation using electric heat elements.

Heat Pump Heating Sequence

Sequence for heating operation with a heat pump.

Pre-Start Installation Checklist

Equipment Maintenance Procedures

Air Filter Maintenance

Guidance on checking, cleaning, and replacing the air filter.

Blower Assembly Service

Steps for removing and replacing the blower assembly.