92-20521-32-15
SUPERSEDES 92-20521-32-14
WARNING
WARNING
!
These instructions are intended as an aid to qualified licensed
service personnel for proper installation, adjustment and
operation of this unit. Read these instructions thoroughly before
attempting installation or operation. Failure to follow these
instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical
shock, property damage, personal injury or death.
ISO 9001:2008
AIR HANDLERS
FEATURING INDUSTRY STANDARD R-410A REFRIGERANT:
RHLL High Efficiency
RHSL Standard Efficiency
INSTALLATION INSTRUCTIONS
refrigerant

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem RHSL-HM2417AA and is the answer not in the manual?

Rheem RHSL-HM2417AA Specifications

General IconGeneral
ModelRHSL-HM2417AA
TypeAir Handler
Airflow1200 CFM
RefrigerantR-410A
Weight110 lbs
Voltage208/230V
Motor TypePSC
Height42 inches
Cooling Capacity24000 BTU
Heating Capacity24000 BTU
Width21 inches

Summary

1.0 SAFETY INFORMATION

3.0 APPLICATIONS

3.1 VERTICAL UPFLOW INSTALLATION

Details on factory configuration for vertical upflow, side return, and ducted return.

3.2 VERTICAL DOWNFLOW CONVERSION

Instructions for converting vertical upflow unit to vertical downflow configuration.

3.3 HORIZONTAL INSTALLATION

Guidance on converting units to horizontal flow and installing components.

4.0 ELECTRICAL WIRING

4.1 POWER WIRING

Details on supplying adequate power, branch circuits, and wire types for unit connection.

4.2 CONTROL WIRING

Guidelines for running low voltage control wire separately from power wiring.

4.3 GROUNDING PROCEDURES

Instructions for proper grounding of the unit to prevent electrical shock.

4.5 ELECTRICAL DATA – BLOWER MOTOR ONLY

4.5A/B BLOWER MOTOR DATA

Electrical data for blower motors, with and without electric heat, for HSL and HLL models.

4.6 ELECTRICAL DATA – WITH ELECTRIC HEAT

4.6A/B/C ELECTRIC HEAT DATA

Electrical data for units with electric heat and heater kit information.

5.0 AIRFLOW PERFORMANCE

5.1 AIRFLOW OPERATING LIMITS

Provides operating limits for cooling and electric heating based on cabinet size.

6.0 DUCTWORK

7.0 REFRIGERANT CONNECTIONS

10.0 CALCULATIONS

11.0 PRE-START CHECKLIST

PRE-START INSTALLATION CHECKLIST

Comprehensive checklist covering unit placement, securing, ductwork, wiring, grounding, and thermostat settings.

12.0 MAINTENANCE

12.1 AIR FILTER MAINTENANCE

Instructions for checking, cleaning, or replacing the air filter.

12.5-12.7 ASSEMBLY REPLACEMENT

Procedures for removing and replacing blower assembly, motor, and wheel.