EasyManua.ls Logo

Rheem RP1448AJ1NA User Manual

Rheem RP1448AJ1NA
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
R-410A HEAT PUMP
OUTDOOR UNITS
92-105074-04-00 (1/15)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully and
keep in a safe place for future
reference by a serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS UNIT.
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
ATTEMPTING INSTALLATION
OR OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY RESULT
IN IMPROPER INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
RP13 (13 SEER)
RP14 (14 SEER) AND RP15 (15 SEER)
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
ST-A1226-01-00

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem RP1448AJ1NA and is the answer not in the manual?

Rheem RP1448AJ1NA Specifications

General IconGeneral
BrandRheem
ModelRP1448AJ1NA
CategoryHeat Pump
Cooling Capacity (BTU/h)48000
Heating Capacity (BTU/h)48000
SEER Rating14
HSPF Rating8.2
Voltage (V)208/230
Phase1
Refrigerant TypeR-410A

Summary

Important Safety Information

WARNINGS

Key safety warnings about installation, grounding, power, and handling.

CAUTIONS

Important notes on R-410A systems, component matching, and potential hazards.

Specifications

Proper Installation

Emphasizes correct sizing and installation for optimal performance and efficiency.

Installation

Choosing a Location

Guidelines for selecting an optimal outdoor unit installation site for performance and service.

Indoor Coil

Emphasizes using matched indoor coils and avoiding R-22 evaporators with R-410A systems.

Leak Testing

Procedure for pressure testing the system with nitrogen to detect leaks.

Tools and Refrigerant

Tools Required for Installing and Servicing R-410A Models

Lists essential tools for working with R-410A systems.

Wiring

Control Wiring

Guidelines for low-voltage thermostat wiring, including wire size and conduit recommendations.

Power Wiring

Information on electrical power requirements, voltage ranges, and conduit for power wiring.

Grounding

Emphasizes the importance of proper unit grounding for electrical safety.

Start-Up

Evacuation Procedure

Step-by-step guide for evacuating the system to remove air and moisture.

Checking Refrigerant Charge

Instructions for verifying and adjusting system refrigerant charge using charts.

Final Charge by Subcooling

Method for fine-tuning system charge using subcooling measurements.

Components and Controls

Diagnostics

Cooling Mechanical Checks Flowchart

A flowchart for diagnosing mechanical issues in cooling mode based on system pressures.

Heating Mechanical Checks Flowchart

A flowchart for diagnosing mechanical issues in heating mode based on system pressures.

General Troubleshooting Chart

A chart listing common symptoms, possible causes, and remedies for system problems.

Cooling Mode Troubleshooting Tips

Indicators and causes for system problems in cooling mode.

Heating Mode Troubleshooting Tips

Indicators and causes for system problems in heating mode.

Wiring Diagrams

Related product manuals