Type | Heat Pump |
---|---|
Cooling Capacity (BTU) | 36000 |
Heating Capacity (BTU) | 36000 |
SEER Rating | 15 |
HSPF Rating | 8.5 |
Refrigerant | R-410A |
Voltage | 208/230 |
Phase | 1 |
Compressor Type | Scroll |
Maximum Operating Ambient Temperature (°F) | 115 |
Minimum Operating Ambient Temperature (°F) | -5 |
Number of Stages | Single |
Guidance on selecting an appropriate installation site for the outdoor unit.
Safety warning regarding securing elevated units to prevent tipping.
Practices for installing refrigerant tubing between indoor and outdoor units.
Guidelines for installing correctly sized refrigerant tubing, including insulation and filter driers.
Procedure for testing the refrigerant system for leaks after installation.
Step-by-step guide for evacuating air and moisture from the system.
Procedure for detecting leaks in the system after evacuation.
Procedure for verifying and adjusting the system's refrigerant charge.
Explanation of pressure controls that protect the compressor from abnormal operation.
Monitors ambient and coil temperatures to determine defrost cycles.
Flowchart for diagnosing mechanical issues in cooling mode.
Flowchart for diagnosing mechanical issues in heating mode.
Flowchart for diagnosing issues related to the defrost system.
Table listing common symptoms, possible causes, and remedies.
Detailed charts for diagnosing system problems and component issues.
Diagnosing and resolving issues leading to compressor overheating.
Guidance for diagnosing system problems in cooling mode based on pressure and temperature indicators.
Guidance for diagnosing system problems in heating mode based on pressure and temperature indicators.