EasyManua.ls Logo

Rheem RP1736HJVXA - Heating Capacity

Rheem RP1736HJVXA
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢ Model: RHMV2421MNACJA
AFR CFM 800
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 18.76 3.19 18.37 3.20 18.10 3.20 18.04 3.43 17.96 3.48
5 3 20.64 3.19 19.72 3.20 19.80 3.22 20.13 3.41 20.95 3.48
14 12 20.82 3.17 20.97 3.25 21.50 3.28 21.29 3.41 21.39 3.48
23 19 23.22 3.20 23.87 3.28 23.95 3.35 23.90 3.42 23.51 3.49
32 28 26.52 3.28 27.10 3.34 26.81 3.41 26.67 3.44 25.97 3.49
41 37 30.74 3.42 30.68 3.44 30.09 3.45 29.59 3.47 28.76 3.49
47 43 34.03 3.54 33.22 3.52 32.40 3.47 31.58 3.50 30.79 3.49
50 47 35.86 3.61 34.59 3.58 33.79 3.47 32.66 3.52 31.87 3.49
59 50 41.90 3.85 38.85 3.75 37.91 3.48 35.90 3.58 35.31 3.50
AFR
m
3
/h
1,359
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-20.6 -21.7 5.50 3.19 5.38 3.20 5.30 3.20 5.29 3.43 5.26 3.48
-15 -16.1 6.05 3.19 5.78 3.20 5.80 3.22 5.90 3.41 6.14 3.48
-10 -11.1 6.10 3.17 6.14 3.25 6.30 3.28 6.24 3.41 6.27 3.48
-5 -7.2 6.81 3.20 6.99 3.28 7.02 3.35 7.00 3.42 6.89 3.49
0 -2.2 7.77 3.28 7.94 3.34 7.86 3.41 7.82 3.44 7.61 3.49
5 2.8 9.01 3.42 8.99 3.44 8.82 3.45 8.67 3.47 8.43 3.49
8.3 6.1 9.97 3.54 9.74 3.52 9.50 3.47 9.26 3.50 9.02 3.49
10 8.3 10.51 3.61 10.14 3.58 9.90 3.47 9.57 3.52 9.34 3.49
15 10 12.28 3.85 11.39 3.75 11.11 3.48 10.52 3.58 10.35 3.50
¢ Model: RHMV3021SNACJA
AFR CFM 870
Indoor temperature
°FDB 60 65 70 72 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 22.58 3.23 22.11 3.24 21.70 3.24 21.70 3.48 21.62 3.52
5 3 23.28 3.24 22.19 3.24 22.20 3.26 22.64 3.46 23.58 3.53
14 12 25.06 3.21 25.23 3.30 25.86 3.33 25.61 3.45 25.75 3.53
23 19 27.95 3.24 28.72 3.32 28.81 3.40 28.75 3.46 28.31 3.53
32 28 31.92 3.33 32.61 3.38 32.26 3.46 32.08 3.49 31.27 3.54
41 37 37.00 3.47 36.91 3.48 36.21 3.50 35.59 3.52 34.62 3.54
47 43 40.95 3.59 39.98 3.57 39.00 3.52 38.03 3.55 37.05 3.54
50 47 43.16 3.66 41.63 3.63 40.66 3.52 39.30 3.57 38.37 3.54
59 50 50.43 3.91 46.75 3.80 45.61 3.53 43.19 3.63 42.52 3.55
AFR
m
3
/h
1,478
Indoor temperature
°CDB 15.6 18.3 21.1 22.2 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-20.6 -21.7 6.62 3.23 6.48 3.24 6.36 3.24 6.36 3.48 6.34 3.52
-15 -16.1 6.82 3.24 6.50 3.24 6.51 3.26 6.63 3.46 6.91 3.53
-10 -11.1 7.35 3.21 7.39 3.30 7.58 3.33 7.51 3.45 7.55 3.53
-5 -7.2 8.19 3.24 8.42 3.32 8.44 3.40 8.43 3.46 8.30 3.53
0 -2.2 9.36 3.33 9.56 3.38 9.45 3.46 9.40 3.49 9.16 3.54
5 2.8 10.84 3.47 10.82 3.48 10.61 3.50 10.43 3.52 10.15 3.54
8.3 6.1 12.00 3.59 11.72 3.57 11.43 3.52 11.14 3.55 10.86 3.54
10 8.3 12.65 3.66 12.20 3.63 11.92 3.52 11.52 3.57 11.25 3.54
15 10 14.78 3.91 13.70 3.80 13.37 3.53 12.66 3.63 12.46 3.55
- 11 -
4-2. Heating capacity 4. Capacity table
DUCT TYPE
RHMV2421-4821*NACJ
A
DUCT TYPE
RHMV2421-4821*NACJ
A

Table of Contents

Other manuals for Rheem RP1736HJVXA

Related product manuals