Model RRRL- Serie
s
B048CK10 B048JK08(E/X) B048JK10(E/X) B060CK10
Cooling Performance
1
Continued ->
Gross Cooling Capacity (2nd Stage) Btu [kW] 48,500 [14.21] 48,500 [14.21] 48,500 [14.21] 60,500 [17.73]
SEER
2
15 15 15 14.2
EER (1st stage / 2nd stage) 12.7/11.5 12.7/11.5 12.7/11.5 12/10.7
ARI Rated CFM (1st / 2nd stage) [L/s] 1050/1600 [495/755] 1050/1600 [495/755] 1050/1600 [495/755] 1250/1850 [590/873]
ARI Net Cooling Capacity (1st / 2nd stage) Btu [kW] 34,800/47,000 [10.2/13.77] 34,800/47,000 [10.2/13.77] 34,800/47,000 [10.2/13.77] 41,800/58,000 [12.25/16.99]
Net Sensible Capacity (1st / 2nd stage) Btu [kW] 24,820/34,480 [7.27/10.1] 24,820/34,480 [7.27/10.1] 24,820/34,480 [7.27/10.1] 30,000/42,280 [8.79/12.39]
Net Latent Capacity (1st / 2nd stage) Btu [kW] 9,980/12,520 [2.92/3.67] 9,980/12,520 [2.92/3.67] 9,980/12,520 [2.92/3.67] 11,800/15,720 [3.46/4.61]
Net System Power (1st / 2nd stage) kW 2.73/4.1 2.73/4.1 2.73/4.1 3.48/5.4
Heating Performance (Gas)
4
Heating Input Btu [kW] 100,000 [29.3] 80,000 [23.44] 100,000 [29.3] 100,000 [29.3]
Heating Output Btu [kW] 81,000 [23.73] 62,000 [18.17] 77,000 [22.56] 81,000 [23.73]
Temperature Rise Range ºF [ºC] 45-85 [25/47.2] 40-70 [22.2/38.9] 45-85 [25/47.2] 45-85 [25/47.2]
AFUE % 80 80 80 80
Steady State Efficiency (%) 81 81 81 81
No. Burners 5 4 5 5
No. Stages 1 1 1 1
Gas Connection Pipe Size in. [mm] 0.5 [12.7] 0.5 [12.7] 0.5 [12.7] 0.5 [12.7]
Compressor
No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
5
78 78 78 78
Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 16.23 [1.51] 16.23 [1.51] 16.23 [1.51] 16.23 [1.51]
Rows / FPI [FPcm] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9] 2 / 22 [9]
Indoor Coil - Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69]
Rows / FPI [FPcm] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6] 2 / 15 [6]
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
Drain Connection No./Size in. [mm] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05] 1/0.75 [19.05]
Outdoor Fan - Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8]
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1
CFM [L/s] 3300 [1557] 3300 [1557] 3300 [1557] 3300 [1557]
No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP
Motor RPM 850 850 850 1075
Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x229] 1/10x9 [254x229] 1/10x9 [254x229] 1/12x9 [305x229]
Drive Type/No. Speeds Direct/11 Direct/11 Direct/11 Direct/11
No. Motors 1 1 1 1
Motor HP 3/4 3/4 3/4 1
Motor RPM 1050 1050 1050 1050
Motor Frame Size 48 48 48 48
Filter - Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No
(NO.) Size Recommended in. [mm x mm x mm] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x30 [25x610x762]
Refrigerant Charge Oz. [g] 169.6 [4808] 169.6 [4808] 169.6 [4808] 165.8 [4700]
Weights
Net Weight lbs. [kg] 554 [251] 557 [253] 562 [255] 571 [259]
Ship Weight lbs. [kg] 565 [256] 568 [258] 573 [260] 582 [264]
NOTES:
1. Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner
Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance limit ettings and rating data were established and approved under laboratory test conditions using American National Standard Institute standards.
Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
4. AFUE is rated in accordance with DOE test procedures.
5. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
G
GENERAL DATA - RRRL- MODELS
NOMINAL SIZES 2-5 TONS [7-15.8 kW]