Draining the Water Heater (cont.)
Preferred Drain Method
Isolator valve kits may be purchased from the
manufacturer, distributor, or place of purchase� The kits
include two full port isolation valves to be used in the
inlet and outlet water lines� It is highly recommended
to install isolator valve kits because these kits provide
a means for full diagnostic testing and ease of system
flushing�
Freeze Protection
!
WARNING:
Failure to drain the water heater can cause serious
personal injury from scalding and/or product
damage.
Whenever the water heater may be exposed to freezing
conditions, precautions should be taken to help prevent
the water heater from freezing�
Freezing conditions come from the ventilation system
on direct-vent models and from exposure to cold air on
outdoor models�
All of these water heaters are equipped with a freeze
protection electric heater� This heater helps prevent
freezing inside the water heater down to outside
temperature of -30°F (-35°C) on indoor installations
and approximately -4°F (-20°F) on outdoor installations�
These temperatures are all based on temperatures
without wind�
The heater only protects the internal components of the
water heater
NOTICE:
Unplugging or disconnecting the power supply to
the water heater will also disconnect the power to
the heater.
External piping and valves require additional freeze
protection� One method is to wrap insulation around the
piping and valves�
Another method is to turn on a hot water faucet and leave
a small amount of water running at a faucet� This will
help protect the water heater, piping, and valves from
freezing�
If power outages occur during freezing conditions, it is
recommended to completely drain the water heater to
help prevent damage to the unit� See "Draining the Water
Heater�" Once power is restored, refill the water heater
and check for frozen or leaking components�
Components or heat exchangers damaged by freezing
conditions is not covered under manufacturer's warranty
Running Water Freeze Protection
Turn off the water heater by pressing the POWER ON/OFF
button on the control panel�
Close the gas shut-off valve(s)�
Open a hot water faucet slightly until the water stream is
approximately 1/8 in� (0�3 cm)� Be sure to check the flow