EasyManua.ls Logo

Rheem STELLAR 850 Series - Page 21

Rheem STELLAR 850 Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WATER SUPPLIES
21
SATURATION INDEX
The saturation index (SI) is used as a measure of the water’s corrosive or scaling
properties. The saturation index figures stated are calculated using a water
temperature of 80°C.
In a corrosive water supply, the water can attack copper parts and cause them
to fail.
In a scaling water supply calcium carbonate is deposited out of the water onto
any hot metallic surface.
Where the saturation index exceeds +0.40, the water is very scaling. An
expansion control valve must be fitted on the cold water line after the non-return
valve to protect and for the Rheem warranty to apply to the temperature pressure
relief valve and water heater cylinder.
Water which is scaling may be treated with a water softening device to reduce
the saturation index of the water.
Refer to the Saturation Index chart on page 21.
Refer to the cold water connection detail on page 36 for the position of the
expansion control valve.
corrosive
SATURATION INDEX
(calculated @ 80°C water temperature)
very corrosive very scaling
scaling
-1.0
WITHIN WARRANTY
SPECIFICATION
+0.8
SATURATION INDEX (SI)
GAS STORAGE WATER HEATERS
+0.4
no warranty applies
to a:
temperature pressure relief
valve or a water heater
cylinder unless an expansion
control valve is fitted.
0

Related product manuals