SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103 4-10 SM
4.2.2 SERIES SERVICE CALL CONDITIONS
There are 4 levels of service call conditions.
Level Definition Reset Procedure
A
Fusing unit SCs displayed on the operation
panel. The machine is disabled. The operator
cannot reset the SC.
Enter SP mode, then turn the
main power switch off and on.
B
SCs that disable only the features that use the
defective item. These SCs are not shown to the
operator under normal conditions. They are
displayed on the operation panel only when the
defective feature is selected.
Turn the main power switch off
and on.
C
SCs that are not shown on the operation panel.
They are internally logged.
Logging only
D
Turning the operation switch (or main power
switch) off then on resets these SCs. These SCs
are displayed on the operation panel and
displayed again if the error reoccurs.
Turn the operation switch (or
main power switch) off and on.