EasyManua.ls Logo

Ricoh B234 - Page 27

Ricoh B234
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE CALL CONDITIONS
SM 4-25 B234/B235/B236/D101/D102/D103
Trouble-
shooting
Drum Potential Sensor Error 5: ID Sensor Pattern Potential
SC438 B
When the ID sensor potential
(Vp) was measured after a cold
start, or at the end of a job, the
total of this reading and the
value of the setting of SP2201
004 did not exceed 800V
(development unit power pack
output) after 10 continuous
samplings.
Drum potential sensor defective
BCU defective
IOB defective
Poor drum unit connection or connectors
defective
Poor drum ground connection
LD defective
Poor drum cleaning ground connection
Drum worn
Dirty laser optics
Drum Potential Sensor Error 6: Vh Abnormal
SC439
When the LD power was adjusted
during auto process control, the first
value detected for the Vh pattern
(used to set standard drum
potential for halftones)
exceeded -730V.
Drum potential sensor harness,
connector loose, broken, defective
Drum potential sensor defective
LD unit defective (pattern could not be
created)
Transfer Output Error
SC440 B
One of the following conditions was detected
for 17 counts (about 100 ms) when the transfer
voltage was applied with the main motor
operating:
The value for the transfer current was set for
70uA, but the feedback voltage was less
than 0.75V (less than 1.5 KV).
When the feedback current was less than
0.16V (10uA), the feedback voltage was
less than 0.15V (less than 300V) due to a
poor input connection.
When the feedback current was less than
0.16V (10uA), the feedback voltage was
less than 3.05V (over 6.1 KV) due to a poor
output connection.
Transfer power pack
harness, connectors loose
or broken
Transfer power pack
harness or connectors
have short circuited
Transfer power pack is
defective
Development Motor Lock
SC441 B
While the motor is operating, the motor
lock signal remained LOW for 2 s
Development motor lock due to
overload
IOB defective

Other manuals for Ricoh B234