4.1.14. ADF Test (Function 10)
1. FU 6 1 9 9 5
then immediately Y
FUNCTION KPAD/NEXT
SERVICE FUNCTIONS
2. 1 0 Y
0-LAMP 1-ADF
2-SHADING
3. 1
START
ADF
4. Place a document in the feeder,
then press S .
5. To stop the test, press s
6. Finish: N FU
4.1.15. Shading (Function 10)
Use this to reset the shading level after a RAM clear has been done.
1. FU 6 1 9 9 5
then immediately Y
FUNCTION KPAD/NEXT
SERVICE FUNCTIONS
2. 1 0 Y
0-LAMP 1-ADF
2-SHADING
3. 2
START
SET SHADING
4. Place a Shading Chart in the feeder,
then press S
NOW SETTING SHADING
If test is successful, the display shows "SET SHADING".
If test is unsuccessful, the display shows "NG".
5. Finish: N FU
NOTE: A Shading Chart is registrered as a service part, P/N H0689300.
SERVICE TABLES AND PROCEDURES August 7th, 1995
SERVICE LEVEL FUNCTIONS
4-8