Address Function Unit Remarks
807F38
(006738)
International dial tone detection
time
20 ms If 807F38 contains FF, the
machine pauses for the
pause time (807F3D /
807F3E).
807F39
(006739)
International dial tone reset time
(LOW)
807F3A
(00673A)
International dial tone reset time
(HIGH)
807F3B
(00673B)
International dial tone continuous
tone time
807F3C
(00673C)
International dial tone permissible
drop time
807F3D
(00673D)
International dial wait interval
(HIGH)
807F3E
(00673E)
International dial wait interval
(LOW)
807F3F
(00673F)
Country dial tone upper frequency
limit (HIGH)
Hz (BCD) See Note 2.
807F40
(006740)
Country dial tone upper frequency
limit (LOW)
807F41
(006741)
Country dial tone lower frequency
limit (HIGH)
807F42
(006742)
Country dial tone lower frequency
limit (LOW)
807F43
(006743)
Country dial tone detection time 20 ms If 807F43 contains FF, the
machine pauses for the
pause time (807F48 /
807F49).
807F44
(006744)
Country dial tone reset time (LOW)
807F45
(006745)
Country dial tone reset time
(HIGH)
807F46
(006746)
Country dial tone continuous tone
time
807F47
(006747)
Country dial tone permissible drop
time
807F48
(006748)
Country dial wait interval (LOW)
807F49
(006749)
Country dial wait interval (HIGH)
807F4A
(00674A)
Time between opening or closing
the Ds relay and opening the Di
relay
1 ms See Notes 4
Function 08 (parameter 11).
807F4B
(00674B)
Break time for pulse dialling 1 ms See Note 4
Function 08 (parameter 12).
807F4C
(00674C)
Make time for pulse dialling 1 ms See Note 4
Function 08 (parameter 13).
807F4D
(00674D)
Time between final Di relay
closure and Ds relay opening or
closing
1 ms See Notes 4
Function 08 (parameter 14).
August 7th, 1995 SERVICE TABLES AND PROCEDURES
NCU PARAMETERS