Address Function Unit Remarks
807F82
(006782)
Bits 0 and 1 - Handset off-hook detection time
Bit 1 0 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit 3 2 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 4 to 7 - Not used
807FA1
(0067A1)
Acceptable CED detection range
(high byte)
BCD (Hz) See Note 2.
807FA2
(0067A2)
Acceptable CED detection range
(low byte)
807FA3
(0067A3)
Not used Do not change the factory
setting.
807FA4
(0067A4)
807FA5
(0067A5)
CED detection time 20 ms
± 20 ms
Factory setting: 200 ms
807FA6
(0067A6)
Not used Do not change the factory
setting.
807FA7
(0067A7)
807FA8
(0067A8)
807FA9
(0067A9)
807FAA
(0067AA)
CNG detection time 20 ms
± 20 ms
Factory setting: 200 ms
807FAB
(0067AB)
CNG on time 20 ms Factory setting: 500 ms
807FAC
(0067AC)
CNG off time 20 ms Factory setting: 200 ms
807FAD
(0067AD)
Number of CNG cycles required
for detection
The data is coded in the
same way as address
807F33 (BRO:006733).
Factory setting: 23[H]
SERVICE TABLES AND PROCEDURES August 7th, 1995
NCU PARAMETERS