T
echnical
B
ulletin
PAGE: 2/8
Reissued: 11-Jan-05
Model:
Model U-P1
Date:
3-Feb-03
No.:
RG071004f
BICU
Symptom Corrected Version
White lines.
Note: The “Doctor roller reverse mode” was changed to decrease
the amount of clogged toner in between the development roller
and doctor roller.
New: Reverse once
Reverse/Forward
Old: Reverse twice
Reverse/Forward/Reverse/Forward
Note: Along with this BICU version, be sure to update the main
unit controller firmware to v2.30 or later.
1.49