RB051007
T
echnical
B
ulletin
PAGE: 1/1
Model:
Model U-P1
Date:
21-May-03
No.:
RG071006
Subject:
Blank area at the one side of the development unit
Prepared by:
Y.Urushihara
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
SYMPTOM
A blank area may appear on one side of the image (development unit front or rear).
CAUSE
The development unit front gears engage their mainframe counterparts slightly differently
than the rear gears.
SOLUTION
Rotate the mainframe gears manually, removing the development unit(s) on which the
symptom occurs, then reinstall the development unit(s).
Mainframe gears