Main Unit Controller
Symptom Corrected Version
1.
SC687 occurs with multi-prints onto B4 (B/W).
2.
Modified in accordance with BCU v1.47a modification. For
details, please see RTB #RG071004d.
NOTE: Along with this main unit controller version, be sure to update
the BICU firmware to v1.47a or later.
V2.29
Merged PCL job cannot print (TechMail#TS030100).
V2.28.2
1. The following SP modes have been added.
For details, please refer to BICU firmware release note RB051004c: BICU
v1.44A.
SP2-400-008: Cleaning Bias LL1: OPC lubrication time
SP2-401-008: Cleaning Bias LL2: OPC lubrication time
SP2-402-008: Cleaning Bias NN1: OPC lubrication time
SP2-403-008: Cleaning Bias NN2: OPC lubrication time
SP2-404-008: Cleaning Bias HH: OPC lubrication time
[0 to 2000/ 1400 / 10 Volt/step]
2. Minimum value changed for SP2-941-01, -02 (OPC lubrication time).
Minimum increased from 0 to 6:
SP2-941-01: Job End: [6
~ 30 / 14 / 1 s/step]
SP2-941-02: OPC Lubrication Interval: [6
~ 60 / 10 / 1 s/step]
NOTE: Along with this main unit controller version, be sure to update the
BICU firmware to v1.44A or later.