SP2
New defaults
(Old default)
PaperTrans_LL1 (Paper Transfer LL1)
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
1 Nrml/1st/-297
Sets the paper transfer current when absolute humidity
AH (g/m
3
) is in the following range:
0 < AH 3.5 (this is the ‘LL1’ humidity range)
Adjust only if there are problems with insufficient transfer
in the image area of the copy for a particular paper type
or mode, or in response to field problems as directed by
technical support staff.
[0 ~ 70.0 /
25.0
(32.0) / 0.2
µ
A/step]
2 Nrml/1st/257-296
[0 ~ 70.0 /
25.0
(34.0) / 0.2 µA/step]
3 Nrml/1st/210-256
[0 ~ 70.0 /
25.0
(36.0) / 0.2 µA/step]
4 Nrml/1st/129-209
[0 ~ 70.0 /
25.0
(39.0) / 0.2 µA/step]
5 Nrml/1st/-128
[0 ~ 70.0 / 25.0 (42.0 / 0.2 µA/step]
6 Mid/1st/-297
[0 ~ 70.0 / 26.0 (33.0) / 0.2 µA/step]
7 Mid/1st/257-296
[0 ~ 70.0 /
26.0
(35.0) / 0.2
µ
A/step]
8 Mid/1st/210-256
[0 ~ 70.0 /
26.0
(37.0) / 0.2
µ
A/step]
9 Mid/1st/129-209
[0 ~ 70.0 /
26.0
(40.0) / 0.2
µ
A/step]
10 Mid/1st/-128
[0 ~ 70.0 /
26.0
(43.0) / 0.2 µA/step]
11 Thk/1st/-297
[0 ~ 70.0 /
14.0
(16.0) / 0.2 µA/step]
12 Thk/1st/257-296
[0 ~ 70.0 /
15.0
(19.0) / 0.2 µA/step]
13 Thk/1st/210-256
[0 ~ 70.0 / 16.0 (21.0) / 0.2 µA/step]
14 Thk/1st/129-209
[0 ~ 70.0 / 18.0 (24.0) / 0.2 µA/step]
15 Thk/1st/-128
[0 ~ 70.0 /
20.0
(27.0) / 0.2
µ
A/step]
16 Nrml/2nd/-297
[0 ~ 70.0 /
28.0
(38.0) / 0.2
µ
A/step]
17 Nrml/2nd/257-296
[0 ~ 70.0 /
30.0
(40.0
)
/ 0.2
µ
A/step]
18 Nrml/2nd/210-256
[0 ~ 70.0 /
28.0
(42.0) / 0.2 µA/step]
19 Nrml/2nd/129-209
[0 ~ 70.0 /
28.0
(43.0) / 0.2 µA/step]
20 Nrml/2nd/-128
[0 ~ 70.0 /
28.0
(44.0) / 0.2 µA/step]
21 Mid/2nd/-297
[0 ~ 70.0 / 29.0 (39.0) / 0.2 µA/step]
22 Mid/2nd/257-296
[0 ~ 70.0 / 31.0 (41.0) / 0.2 µA/step]
23 Mid/2nd/210-256
[0 ~ 70.0 /
29.0
(43.0) / 0.2
µ
A/step]
24 Mid/2nd/129-209
[0 ~ 70.0 /
29.0
(44.0) / 0.2
µ
A/step]
25 Mid/2nd/-128
[0 ~ 70.0 /
29.0
(45.0) / 0.2
µ
A/step]
26 Thk/2nd/-297
[0 ~ 70.0 /
12.0
(16.0) / 0.2 µA/step]
27 Thk/2nd/257-296
[0 ~ 70.0 /
16.0
(19.0) / 0.2 µA/step]
28 Thk/2nd/210-256
[0 ~ 70.0 /
20.0
(21.0) / 0.2 µA/step]
29 Thk/2nd/129-209
[0 ~ 70.0 / 24.0 / 0.2 µA/step]
30 Thk/2nd/-128
[0 ~ 70.0 / 28.0 (26.0) / 0.2 µA/step]
31 OHP/297
[0 ~ 70.0 /
16.0
/ 0.2
µ
A/step]
310*
32 OHP/210
[0 ~ 70.0 /
20.0
(22.0) / 0.2
µ
A/step]
PaperTrans_LL2 (Paper Transfer LL2)
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
311*
1 Nrml/1st/-297
Sets the paper transfer current when absolute humidity
AH (g/m
3
) is in the following range:
3.5 < AH
8.0 (this is the ‘LL2’ humidity range)
See SP2-310 for comments.
[0 ~ 70.0 /
27.0
(36.0) / 0.2
µ
A/step]
311* 2 Nrml/1st/257-296
[0 ~ 70.0 /
28.0
(38.0) / 0.2
µ
A/step]

Related product manuals