T
echnical
B
ulletin
PAGE: 2/6
Reissued: 3-Dec-03
Model:
Model U-P1
Date:
3-Feb-03
No.:
RG071004d
BICU
Symptom Corrected Version
1. SP modes newly added:
SP2-922-001 (Development Clutch ON after Job End)
Determines whether or not a small amount of toner is applied to
the OPC belt surface in order to ensure proper belt cleaning.
0: OFF
1: ON (Default)
Note: Although the above is not a new SP mode, it has been made
selectable.
SP2-923-001 (Lubricant after Toner End
)
Sets whether or not lubrication is applied at Toner End recovery.
0: OFF
1: ON (Default)
The following two SP modes control the interval for performing
reverse rotation on the M and K doctor rollers at job end, in order
to ensure toner clumps do not form.
Note: Although the following are not new, the intervals for these
existing operations have been made selectable.
SP3-913-001 (Doctor roller rotation interval M)
[1 ~ 50 / 1 / 1 /step]
SP3-913-002 (Doctor roller rotation interval K)
[1 ~ 50 / 1 / 1 /step]
V1.47A