1.1 Technical Parameter
Model
RK6006
Input voltage range
12-68.00V
Output voltage range
0-60.00V
Output current range
0-6.000A
Output power range
0-360.0W
Input voltage measurement resolution
0.01V
Output voltage setting measurement resolution
0.01V
Output current setting measurement resolution
0.001A
Input voltage measurement accuracy
±(1%+5 digits)
Output voltage accuracy between setting and
measurement
±(0.3%+3 digits)
Output current accuracy between setting and
measurement
±(0.5%+5 digits)
Output ripple typical
100mV VPP
Working temperature range
-10
~40
External sensor Temperature detection range:
-10
~100
/0
~200
External sensor Temperature detection
accuracy:
±3
/±6
External sensor parameter
10K NTC B3950
Constant voltage mode response time
2ms
0.1A-5A load
Constant voltage mode load regulation
±(0.1%+2 digits)
Constant current mode load regulation
±(0.1%+3 digits)
Capacity measurement range
0-9999.99Ah
Energy measurement range
0-9999.99Wh
Constant voltage mode response time
±2
Max output voltage
input voltage÷1.1
-1
External cooling fan start condition
Output current>4A or
System temperature>45