Montage und Bedienungsanleitung
Installation, use and maintenance instructions
Instructions pour installation, utilisation et entretien
2915916 (7) - 04/2015
Gas-Gebläsebrenner
Forced draught gas burners
Brûleurs gaz à air souff
Zweistufiger gleitender Betrieb
Two-stage progressive operation
Fonctionnement à 2 allures progressives
CODE
MODELL
MODEL - MODELE
TYP - TYPE
3752118 GAS 3/2 521 T1
3752218 GAS 4/2 522 T1
3752318 - 20102494 GAS 5/2 523 T1
3752418 GAS 6/2 524 T1
3752518 GAS 7/2 525 T1
D
GB
F

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Riello GAS 3/2 and is the answer not in the manual?

Riello GAS 3/2 Specifications

General IconGeneral
BrandRiello
ModelGAS 3/2
CategoryIndoor Fireplace
LanguageEnglish

Summary

Declaration of Conformity

Manufacturer and Product Details

Details about the manufacturer, product, and compliance standards.

Technical Data

General Specifications

Includes burner description, dimensions, output, fuel, operation, and boiler compatibility.

Optional Accessories

Kits for modifying or enhancing burner performance and features.

Performance Data and Graphs

Graphs and explanations of firing rates, gas pressure, and boiler compatibility.

Test Boiler and Gas Pressure Charts

Configuration of test boilers and charts for gas pressure requirements.

Installation Procedures

Boiler Plate and Blast Tube Preparation

Steps for preparing the boiler plate and selecting the blast tube length.

Securing Burner and Head Adjustment

Instructions for mounting the burner and initial combustion head setup.

Gas Supply System Installation

Guidance on connecting the gas supply line and train components.

Electrical Wiring and Diagrams

Overview of wiring diagrams, safety warnings, and symbol keys.

Three-Phase Electrical Connections

Specific wiring for three-phase models and thermal relay calibration.

Burner Setup and Operation

Pre-Ignition Adjustments

Setting pressure switches, manometer, and servomotor before first firing.

Burner Startup Sequence

Step-by-step process from pre-purging to ignition and stage operation.

Burner Output and Safety Adjustments

Procedures for setting ignition, 1st, and 2nd stage outputs, and safety switches.

Maintenance and Troubleshooting

Final Checks and Maintenance Procedures

Verifying operation, performing routine maintenance, and opening the burner.

Troubleshooting Guide by Fault Code

Table correlating fault signals with causes and recommended remedies.

Diagnostics and Flame Detection

Using LED signals for flame detection time and diagnosing operational faults.