Chapter 2 Command System  RIGOL 
DG800 Programming Guide  2-33 
:MEM:STAT:NAME? 2           /*Queries the filename of the state file stored in storage location 2 of the 
internal non-volatile memory of the instrument. The query returns 
"123.RSF".*/ 
 
 
:MEMory:STATe:RECall:AUTO 
 
Syntax   
:MEMory:STATe:RECall:AUTO {ON|1|OFF|0} 
:MEMory:STATe:RECall:AUTO? 
 
Description 
Recalls the configuration of the instrument to last (ON or 1) or default (OFF or 0) at next power-on. 
Queries the configuration of the instrument at next power-on. 
 
Parameter 
 
Remarks   
  Last (ON or 1): the instrument recalls the last system configuration (including all the system 
parameters and states except the channel on/off state) at the next power-on. 
  Default (OFF or 0): the instrument recalls the factory defaults (except the parameters that will not be 
affected by factory default settings, refer to "Factory Setting") at power-on. 
 
Return Format 
The query returns ON or OFF. 
 
Example 
:MEM:STAT:RECall:AUTO ON   /*Recalls the last system configuration at the next power-on.*/ 
:MEM:STAT:RECall:AUTO?          /*Queries the configuration of the instrument at next power-on. The query 
returns ON.*/ 
 
 
:MEMory:STATe:VALid? 
 
Syntax 
:MEMory:STATe:VALid? {0|1|2|3|4|5} 
 
Description 
Queries whether a state file is found in the specified storage location of the internal non-volatile memory of 
the instrument. 
 
Parameter 
 
Remarks 
The internal non-volatile memory of the instrument provides 6 storage locations for state files. 0 to 5 
represents the state files stored in the specified locations respectively. 
 
Return Format 
The query returns 1 or 0. 1 denotes that a state file is already found in the specified storage location; and 
0 denotes that no state file is found in the specified storage location.