Chapter 2 Front Panel Operations  RIGOL 
DL3000 User’s Guide  2-95 
In the system setting tab, press the Up/Down arrow key to switch the parameter 
focus to "Sense", and then press the Left/Right arrow key or use the knob to enable 
or disable the Sense function. 
Turn On/Off Voltage Monitoring Output Terminal 
 
The terminal outputs the 0-to-+10 V voltage signal, which indicates the zero-to-full 
scale real-time input voltage. 
 
In the system setting tab, press the Up/Down arrow key to switch the parameter 
focus to "Vmon_EXT", and then press the Left/Right arrow key or use the knob to 
enable or disable the voltage monitoring function. 
 
Turn On/Off Current Monitoring Output Terminal 
 
The terminal outputs the 0-to-+10 V voltage signal, which indicates the zero-to-full 
scale real-time input current. 
 
In the system setting tab, press the Up/Down arrow key to switch the parameter 
focus to "Imon_EXT", and then press the Left/Right arrow key or use the knob to 
enable or disable the current monitoring function. 
 
 
Set the Short Circuit 
 
The load can serve as a short-circuit system at the input terminal. The short circuit 
can be toggled on/off. You can set the short circuit to be "TOGGLE". You need to 
press and hold the SHORT key on the front panel of the load to enable the short 
circuit function. Once you release the key, the short circuit function is disabled. If you 
set the short circuit to be "HOLD", when you press the SHORT key on the front 
panel of the load, the short circuit function is always enabled. When you press the 
SHORT key again, the short circuit function is disabled. 
 
In the system setting tab, press the Up/Down arrow key to switch the parameter 
focus to "SHORT", and then press the Left/Right arrow key or use the knob to set the 
short circuit to be "TOGGLE" or "HOLD". 
 
 
Turn On/Off Log Recording 
 
After you enable the log recording function, the system stores the log recorded 
(including the key operation and prompt message) to the internal non-volatile 
memory. Up to 100 log files can be kept in the memory. 
 
In the system setting tab, press the Up/Down arrow key to switch the parameter 
focus to "Log", and then press the Left/Right arrow key or use the knob to enable or