Portable Multi-Gas Monitor
RX-8500/RX-8700
Data Logger Management Program
SW-RX-8500/8700(EX)
Operating Manual

Table of Contents

Other manuals for Riken Keiki RX-8700

Questions and Answers

  • M
    Maria DunlapAug 19, 2025
    What to do if my Riken Keiki Microphone displays a low flow rate alarm [FAIL LOW FLOW]?
    • C
      Caroline WilliamsSep 12, 2025
      If your Riken Keiki Microphone displays a low flow rate alarm, it could be due to several reasons. First, check the gas sampling hose for any damage or signs of water or oil being drawn in. Second, inspect the gas sampling hose for any blockages, clogs, or twists. If the gas monitor was powered on at a low temperature or hasn't been used for a while, try cycling the power several times to see if the pump starts operating. If none of these steps work, the pump may have deteriorated, and you should contact RIKEN KEIKI to replace it.
  • M
    Marie BrownAug 21, 2025
    Why won't my Riken Keiki Microphone calibrate to air [FAIL AIR CAL]?
    • S
      Steven MillerAug 21, 2025
      If your Riken Keiki Microphone won't calibrate to air, ensure that fresh air is properly supplied around the gas monitor and perform the air calibration again. If the issue persists, a sensor may have failed, and you should contact RIKEN KEIKI for repair.
  • K
    Kathryn MarshallAug 23, 2025
    What to do if the batteries of Riken Keiki Microphone cannot be charged (Lithium ion battery unit only)?
    • M
      Michelle SavageAug 23, 2025
      If the batteries of your Riken Keiki Microphone aren't charging (Lithium ion battery unit only), first, make sure the AC plug and DC plug of the AC adapter are properly connected. If that doesn't resolve the issue, there may be a charging circuit abnormality, and you should contact RIKEN KEIKI for repair. Also, keep in mind that if the batteries are already fully charged, the charging indicator lamp won't turn on when you try to charge them again.
  • Z
    zperezAug 26, 2025
    How to fix clock abnormalities [FAIL CLOCK] in Riken Keiki Microphone?
    • B
      Becky HamiltonAug 26, 2025
      If you are experiencing clock abnormalities with your Riken Keiki Microphone, try setting the date and time. If the issue continues to occur, the built-in clock may be malfunctioning, and you should contact RIKEN KEIKI for a replacement.
  • M
    Makayla MoyerAug 27, 2025
    What to do if error occurs during communication with Riken Keiki RX-8700?
    • M
      Mr. Douglas MyersAug 28, 2025
      If communication errors occur with your Riken Keiki Monitor, it might be due to scattered infrared light interference. Try eliminating any devices emitting IR light in the vicinity. Also, avoid moving the RX-8500/8700 main unit during communication to prevent errors.
  • G
    Gregory BarrAug 30, 2025
    Why communication is not possible with Riken Keiki Monitor?
    • K
      Karen GrantAug 30, 2025
      If communication with your Riken Keiki Monitor is not possible, the main unit's position might be inappropriate. Try adjusting its position. Alternatively, another device using infrared (IR) might be interfering. Turn off other IR devices or prevent their interference.
  • A
    Adam JacksonAug 31, 2025
    What to do if the Riken Keiki Gas Detectors reading rises and remains?
    • J
      johnsondorothySep 1, 2025
      If the reading on your Riken Keiki Gas Detectors rises or drops and remains at that level, it could be due to several reasons. First, try performing an air calibration, as the sensor output may be drifting or environmental changes may be affecting the reading. Check for any interference gases, like solvents, and address them accordingly. Also, consider the possibility of a slow gas leak. If a leak is suspected, take immediate action as you would during a gas alarm. The oxygen sensor is particularly sensitive to air pressure, so air calibration may help.
  • J
    Jane AlexanderSep 3, 2025
    Why won't my Riken Keiki Gas Detectors turn on?
    • R
      Ray AdamsSep 3, 2025
      If your Riken Keiki Gas Detectors won't turn on, the battery level may be too low, or the battery unit might not be installed correctly. If you're using a dry battery unit, replace all three batteries with new ones in a safe place. If it's a Li-ion battery unit, charge it in a safe place. Also, ensure the battery unit is properly attached to the main unit.
  • A
    Ashley GardnerSep 5, 2025
    What to do if Riken Keiki Gas Detectors displays a low battery voltage alarm [FAIL BATTERY]?
    • R
      Roberto LoganSep 5, 2025
      If your Riken Keiki Gas Detectors displays a low battery voltage alarm, it means the battery level is low. If you're using a dry battery unit, turn off the power and replace the dry batteries with new ones in a safe place. If you have a Li-ion battery unit, turn off the power and charge it in a safe place.
  • T
    Tina RichmondSep 7, 2025
    What to do if my Riken Keiki Gas Detectors shows system abnormalities [FAIL SYSTEM]?
    • L
      Lisa NunezSep 7, 2025
      If your Riken Keiki Gas Detectors displays a system abnormality message [FAIL SYSTEM], a main unit circuit abnormality has occurred. Contact your sales outlet or closest RIKEN KEIKI dealer to request repairs.

Summary

Preface

Purpose and Features of the Program

Explains the purpose and features of the software program for data management.

Installation and Uninstallation

Software Installation and Procedure

Instructions and steps for installing the software onto a Windows-based PC.

Uninstallation

Instructions on how to uninstall the software from a Windows PC.

How to Operate

Download Screen and Procedures

Overview of the download screen and steps for downloading various data types.

Instrument Information Screen

View detailed instrument information, calibration history, and alarm setpoints.

Data Screen and Details

Interface for viewing, deleting, and detailing downloaded data.

Data View Screen Features

Displays detailed data in table/graph, printing, saving, and summary views.

Last Calibration Management

Check expiration dates of downloaded past calibration data.

Configuration and Updates

Set screen for display, unit status, and sending updates to the main unit.

Data Maintenance

Data Storage and Backup

Details on data storage structure and recommendations for backing up data.

Operating Precautions

General Operating Precautions

Important considerations for safe and proper operation of the software.

Troubleshooting

Communication Troubleshooting

Common issues, causes, and solutions for communication problems.

IrDA Specifications

Infrared Communication Details

Explains IrDA protocol and communication status display.

File Structure

File Organization

Lists files in current directories after installation and during operation.

Software Specifications

Technical Specifications

Details on software OS, capacity, communication settings, and package contents.

Riken Keiki RX-8700 Specifications

General IconGeneral
ModelRX-8700
Measurement Range (LEL)0-100%LEL
Sampling MethodDiffusion
AlarmYes
Detection GasO2, CO, H2S
Detection PrincipleElectrochemical (O2, CO, H2S), Catalytic combustion (LEL)
Detection MethodDiffusion
Alarm MethodAudible alarm, Visual alarm, Vibration alarm
Power SourceLithium-ion battery pack
Operating Temperature Range-20°C to +50°C
DisplayLCD