EasyManuals Logo
Home>ring>Extender>Alarm Range Extender

ring Alarm Range Extender User Manual

ring Alarm Range Extender
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Ring Alarm Range Extender User Manual
Date:
Version: 0.1
Page: 7
Parameter
Number
Description
Number
of
Bytes
Default
Min
Max
Format
1
Heartbeats:
This parameter is the number minutes
between heartbeats. Heartbeats are
automatic battery reports on a timer after
the last event.
1
70 (0x46)
1 (0x01)
70 (0x46)
0x01
Unsigned
2
Number of application level retries
attempted for messages either not ACKed
or messages encapsulated via supervision
get that did not receive a report.
1
1 (0x01)
0 (0x00)
5 (0x05)
0x01
Unsigned
3
Application Level Retry Base Wait Time
Period:
The number base seconds used in the
calculation for sleeping between retry
messages.
1
5 (0x05)
1 (0x01)
60 (0x3C)
0x01
Unsigned
4
This parameter allows a user, via software, to
configure the various LED indications on the
device.
1
1 (0x01)
0 (0x00)
1 (0x01)
enum
5
The number of milliseconds waiting for a
Supervisory Report response to a
Supervisory Get encapsulated command
from the device before attempting a retry.
2
1500
(0x5DC)
500 (0x1F4)
5000
(0x1388)
0x01
Unsigned
Notification Command Class, V8
Device Condition
Command Class and Value
Association Group
AC mains power reconnected
Notification Report
Type: 0x08 Power Management
State: 0x03 AC mains reconnected
1 (Lifeline)