Ring Alarm Range Extender User Manual
Date:
Version: 0.1
Page: 8
Device Condition
Command Class and Value
Association Group
AC mains power disconnected
Notification Report
Type: 0x08 Power Management
State: 0x02 AC mains disconnected
1 (Lifeline)
Comm Test Button Pressed
Notification Report
Type: System 0x09
Event: Heartbeat 0x05
1 (Lifeline)
Watchdog Notification
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0x55
Software Fault (Ring)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAA (Ring Value for Soft Fault)
1 (Lifeline)
Software Fault (SDK)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xA9 (SDK Value for Soft Fault)
1 (Lifeline)
Software Reset (Not triggered by failure)
Notification Report
Type: System 0x09
State Value: 0x04 System Software Failure
State Parameter Value = 0xAC
1 (Lifeline)
Power On Reset
Notification Report
Type: 0x08 Power Management
Event Parameter: 0x01 Power has been applied
1 (Lifeline)
Brownout
Notification Report
1 (Lifeline)

Related product manuals