VC Series Manual 7
Vent Terminaon Clearances
INSIDE
CORNER DETAIL
FIXED
CLOSED
OPERABLE
FIXED
CLOSED
OPERABLE
B
B
B
A
J
B
M
C
F
B
B
E
D
L
G
A
H
K
I
[1] A vent shall not terminate directly above a sidewalk or paved driveway
that is located between two single family dwellings and serves both
dwellings.
[2] Permied only if veranda, porch, deck, or balcony is fully open on a
minimum of two sides beneath the oor.
For clearances not specied in ANSI Z223.1/NFPA 54, clearances are in
accordance with local installaon codes and the requirements of the gas
supplier.
Clearance to opposite wall is 24 inches (60 cm).
X
V
AIR SUPPLY INLET
VENT TERMINAL
AREA WHERE TERMINAL
IS NOT PERMITTTED
For indoor models, you must install a vent terminaon to bring in combuson air and expel exhaust.
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line
Ref
Descripon
Canadian Installaons US Installaons
A Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) 12 inches (30 cm)
B Clearance to window or door that may be opened 36 inches (91 cm) 12 inches (30 cm)
C Clearance to permanently closed window * *
D
Vercal clearance to venlated sot, located above the terminal within
a horizontal distance of 2 feet (61 cm) from the center line of the
terminal
* *
E Clearance to unvenlated sot * *
F Clearance to outside corner * *
G Clearance to inside corner * *
H
Clearance to each side of center line extended above meter/regulator
assembly
3 feet (91 cm) within a height 15
feet (4.5 m) above the meter/
*
I Clearance to service regulator vent outlet 36 inches (91 cm) *
J
Clearance to nonmechanical air supply inlet to building or the
combuson air inlet to any other appliance
36 inches (91 cm) 12 inches (30 cm)
K Clearance to a mechanical air supply inlet 6 feet (1.83 m)
3 feet (91 cm) above if within 10
feet (3 m) horizontally
L
Clearance above paved sidewalk or paved driveway located on public
property
7 feet (2.13 m) *
M Clearance under veranda, porch, deck, or balcony 12 inches (30 cm) *

Table of Contents

Other manuals for Rinnai RL75I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai RL75I and is the answer not in the manual?

Rinnai RL75I Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Flow Rate7.5 GPM
Energy Factor0.82
Installation TypeIndoor
Max BTU180, 000 BTU
GPM @ 35° Rise7.5
Minimum BTU Input15, 000 BTU
VentingDirect Vent