Communications Manual Rev 3.10  Software Versions 3.xx 
Page 24 
003R-618-310
 
 
5.3.6.  Read Items 
This command reads one item from the list for the register.  The item to be read is 
given as a parameter to the command.  Each value is returned as a string. 
Command:  CMD_READ_ITEM 
Valid Types:  TYPE_OPTION, TYPE_MENU, TYPE_BITFIELD 
Parameter:  RangeMin ≤ parameter ≤ RangeMax 
Return:  String value 
Error Code:  If no parameter is present, the indicator returns 
ERR_BAD_PARAMETER. 
eg. Read items 0 and 1 from REG_DECIMAL_PLACES 
Read item 0 
200D0128:0
  
 
Response 
810D0128:000000  
 
Read item 1 
200D0128:1
  
 
Response 
810D0128:00000.0