Questions and Answers

  • D
    dyerchristopherAug 25, 2025
    What to do if my Rivacold Air Conditioner has a clogged suction filter?
    • C
      christopherowensAug 26, 2025
      If your Rivacold Air Conditioner's suction filter is clogged, you should clean or replace it.
  • A
    Amber BeltranAug 26, 2025
    What to do if my Rivacold Air Conditioner has ice formed on expansion valve needle?
    • E
      ebakerAug 27, 2025
      If ice has formed on the expansion valve needle of your Rivacold Air Conditioner, remove the ice.
  • K
    kwoodAug 27, 2025
    What to do if my Rivacold Air Conditioner has clogged liquid pipes?
    • L
      Lucas LoweAug 27, 2025
      If the liquid pipes in your Rivacold Air Conditioner are clogged, clean them.
  • L
    Lori NorrisAug 27, 2025
    What to do if my Rivacold Air Conditioner has an expansion valve failure?
    • C
      cynthia22Aug 28, 2025
      If your Rivacold Air Conditioner's expansion valve has failed, replace it.
  • L
    Lori JamesAug 28, 2025
    What to do if my Rivacold Air Conditioner has excess refrigerant?
    • K
      Kara BergAug 28, 2025
      If your Rivacold Air Conditioner has excess refrigerant, remove the excess refrigerant from the system.
  • L
    leedavidAug 29, 2025
    What to do if my Rivacold Air Conditioner has inadequate cooling water flow?
    • K
      Kyle RodriguezAug 29, 2025
      If your Rivacold Air Conditioner has inadequate cooling water flow, check and improve the cooling water flow.
  • T
    Thomas PetersAug 30, 2025
    What to do if my Rivacold Air Conditioner has suction pipes not correctly insulated?
    • A
      Amy MartinezAug 30, 2025
      If the suction pipes of your Rivacold Air Conditioner are not correctly insulated, insulate them correctly.
  • K
    Kaitlyn BrownAug 23, 2025
    What to do if my Rivacold Air Conditioner has a lack of refrigerant?
    • M
      mcconnelljessicaAug 23, 2025
      If your Rivacold Air Conditioner is experiencing a lack of refrigerant, the suggested solution is to add refrigerant to the system.
  • K
    kmasonSep 1, 2025
    What to do if my Rivacold Air Conditioner has a closed shut off valve on oil return pipe?
    • J
      James JacksonSep 1, 2025
      If the shut off valve on the oil return pipe is closed in your Rivacold Air Conditioner, open it.
  • M
    Monique RhodesSep 2, 2025
    What to do if my Rivacold Air Conditioner has a dirty filter on oil return?
    • C
      Caitlin OrtizSep 2, 2025
      If the filter on oil return is dirty in your Rivacold Air Conditioner, clean or replace it.

Summary

Installation

6.1 Installation

Details on unit placement, fixing, and pipe/cable routing.

6.3 Refrigerating Connection

Guidelines for connecting suction and liquid lines with correct diameters.

6.7 Vacuum

Importance and procedure for vacuum setting to remove air and humidity.

6.8 Refrigerant Charge

Steps and safety for charging the system with refrigerant, including liquid state charging.

6.9 Leakage Checks

Methods and importance of checking for refrigerant leaks, especially with new gases.

Starting the Machine

Alarm Signals

Emergency System

Pressure Relief Valve

Maintenance and Cleaning

Troubleshooting Table

Rivacold FSH012Z001 Specifications

General IconGeneral
RefrigerantR410A
Voltage220-240V
Frequency50Hz
Cooling Capacity3.5 kW
Phase1