What to do if my Rivacold Air Conditioner has an imprecise thermometer?
- WwreillySep 14, 2025
If your Rivacold Air Conditioner has an imprecise thermometer, calibrate or replace it.
What to do if my Rivacold Air Conditioner has an imprecise thermometer?
If your Rivacold Air Conditioner has an imprecise thermometer, calibrate or replace it.
What to do if the condenser is dirty in my Rivacold Air Conditioner?
If the condenser of your Rivacold Air Conditioner is dirty, the suggested solution is to clean it.
What to do if my Rivacold Air Conditioner has a clogged suction filter?
If your Rivacold Air Conditioner's suction filter is clogged, you should clean or replace it.
What to do if my Rivacold Air Conditioner has ice formed on expansion valve needle?
If ice has formed on the expansion valve needle of your Rivacold Air Conditioner, remove the ice.
What to do if my Rivacold Air Conditioner has expansion valve capacity too high?
If the expansion valve capacity is too high in your Rivacold Air Conditioner, replace or adjust the expansion valve to reduce capacity.
What to do if my Rivacold Air Conditioner has excess oil in the circuit?
If there is excess oil in the circuit of your Rivacold Air Conditioner, remove excess oil from the circuit.
What to do if my Rivacold Air Conditioner has a clogged expansion valve filter?
If the expansion valve filter is clogged in your Rivacold Air Conditioner, clean or replace it.
What to do if my Rivacold Air Conditioner has a by-pass shut off valve opened or perforated rupture disk?
If the by-pass shut off valve is opened or the rupture disk is perforated in your Rivacold Air Conditioner, inspect and repair the by-pass shut off valve or replace the rupture disk.
What to do if my Rivacold Air Conditioner has a lack of oil?
If your Rivacold Air Conditioner is experiencing a lack of oil, add oil to the system.
What to do if my Rivacold Air Conditioner has clogged discharge pipes?
If your Rivacold Air Conditioner has clogged discharge pipes, clean the clogged discharge pipes.
Details lifting, fixing units, pipe/cable passage, and clearance requirements.
Refers to drawings and documents for evaporator installation.
Covers refrigerating connections, suction line, oil return, and vacuum procedures.
Details the process of charging the system with refrigerant and checking for leaks.
Covers pressure switches, relief valves, and electrical connection requirements.
| Refrigerant | R410A |
|---|---|
| Power Supply | 220-240V/50Hz/1Ph |
| Cooling Capacity | 2.6 kW |
| Air Flow | 500 m³/h |
| Noise Level (Indoor) | 38 dB(A) |