BLOCKSYSTEM FS Rev. 02 02/07
I
UK
F
D
E
BLOCKSYSTEM
FS
MANUALE USO E MANUTENZIONE
USE AND MAINTENANCE HANDBOOK
MODE D’EMPLOI ET D’ENTRETIEN
MANUAL DE USO Y MANTENIMIENTO
BETRIEBS UND WARTUNGSANLEITUNG

Questions and Answers

  • K
    Kevin PerkinsSep 2, 2025
    What to do if my Rivacold Air Conditioner has suction shut off valve closed?
    • K
      Kristopher NashSep 3, 2025
      If the suction shut off valve is closed in your Rivacold Air Conditioner, check it and open it.
  • A
    Amy RojasSep 3, 2025
    What to do if my Rivacold Air Conditioner thermostat set too high or damaged?
    • T
      Thomas PerezSep 3, 2025
      If the thermostat in your Rivacold Air Conditioner is set too high or is damaged, adjust or replace it.
  • C
    Cory JimenezSep 4, 2025
    What to do if my Rivacold Air Conditioner has a discharge shut off valve closed?
    • B
      Brent ColemanSep 4, 2025
      If the discharge shut off valve is closed in your Rivacold Air Conditioner, check the discharge shut off valve and open it.
  • J
    jennifer28Sep 5, 2025
    What to do if my Rivacold Air Conditioner has presence of air or of gas that cannot be condensed?
    • J
      Jessica WeaverSep 5, 2025
      If there is air or gas that cannot be condensed in your Rivacold Air Conditioner, remove any air or uncondensable gas from the system.
  • B
    bpalmerSep 6, 2025
    What to do if my Rivacold Air Conditioner has a connecting rod assembly, bearings or segments worn?
    • A
      abigailbookerSep 6, 2025
      If the connecting rod assembly, bearings, or segments are worn in your Rivacold Air Conditioner, inspect and replace them.

Summary

Installation

6.1 Installation

Details on unit placement, fixing, and pipe/cable routing.

6.3 Refrigerating Connection

Guidelines for connecting suction and liquid lines with correct diameters.

6.7 Vacuum

Importance and procedure for vacuum setting to remove air and humidity.

6.8 Refrigerant Charge

Steps and safety for charging the system with refrigerant, including liquid state charging.

6.9 Leakage Checks

Methods and importance of checking for refrigerant leaks, especially with new gases.

Starting the Machine

Alarm Signals

Emergency System

Pressure Relief Valve

Maintenance and Cleaning

Troubleshooting Table

Rivacold FSH012Z001 Specifications

General IconGeneral
RefrigerantR410A
Voltage220-240V
Frequency50Hz
Cooling Capacity3.5 kW
Phase1

Related product manuals