Do you have a question about the RKI Instruments Beacon 110 and is the answer not in the manual?
| Model | Beacon 110 |
|---|---|
| Type | Controller |
| Output | 4-20 mA |
| Enclosure | NEMA 4X |
| Measurement Range | Dependent on sensor |
| Operating Temperature | -20°C to 50°C |
| Relative Humidity | 0-95% non-condensing |
| Power Supply | 24 VDC |
Briefly describes the Beacon 110 Gas Monitor and the operator's manual.
Details the Beacon 110 as a fixed-mount, single-channel continuous-monitoring gas monitoring controller.
Explains conventions for notes, cautions, and warnings used in the manual.
Lists detailed technical specifications including input power, dimensions, and safety ratings.
Describes the external and internal components of the Beacon 110 gas monitor.
Details the housing, buttons, LEDs, and other external components of the Beacon 110.
Describes the internal components, including PCBs, power supply, and terminal strips.
Explains the AC In, Alarm, Controller, and Detector/Transmitter terminal strips for wiring.
Details relays, AC/DC circuit protection, and ground stud connections.
Illustrates and describes components on the Control PCB, including display and buttons.
Introduces optional accessories like the alarm strobe and horn/strobe.
Describes the optional alarm strobe and horn/strobe accessories and their wiring.
Provides step-by-step instructions for installing the horn/strobe accessory.
Outlines procedures for mounting, wiring, and starting up the Beacon 110.
Provides steps and considerations for physically installing the Beacon 110 housing.
Describes connecting power sources, alarms, recorders, and detector heads.
Covers connecting AC power and DC power or backup battery to the unit.
Details connecting external alarms, recorders, and detectors.
Guides the user through powering up and initiating the Beacon 110.
Describes normal operation, alarm conditions, and responses.
Defines normal operation and what the display shows.
Explains the 4-20 mA signal output behavior under different conditions.
Details how to view and reset minimum and maximum gas readings.
Describes the optional battery charging feature and its requirements.
Explains visual and audible indications for alarm conditions.
Details indications and responses for Alarm 1 conditions.
Details indications and responses for Alarm 2 conditions.
Describes indications and responses for a fail condition.
Describes indications and responses for a low DC power condition.
Explains how to view and change Beacon 110 parameters.
Guides users through accessing and modifying device parameters.
Explains how to select detector head input type and gas type.
Lists and describes the available detector head input types.
Guides the user through selecting the appropriate gas type for the detector.
Covers calibration, fuse replacement, preventive maintenance, and troubleshooting.
Recommends calibration intervals based on application demands.
Explains how to use Calibration Mode for detector heads.
Details calibration steps for different detector head types.
Step-by-step instructions for replacing the unit's AC fuses.
Outlines daily, monthly, and quarterly maintenance procedures.
Describes symptoms, causes, and recommended actions for common problems.
Lists common issues and their solutions for the Beacon 110 controller.
Lists replacement parts and accessories with their part numbers.
Provides a quick reference for button combinations and operational modes.
Summarizes button functions, combinations, and adjustable parameters.