DIGITAL
NON-PROGRAMMABLE
THERMOSTAT
9400
ELECTRIC
E
GAS
G
OIL
O
®
NeW
1 Heat / 1 Cool
User's Manual
Quick Start
Installation
Application
The Robertshaw 9400 is a single-stage thermostat designed to control
24 VAC gas or electric heating and cooling systems or single-stage heat
pump.
Features
Low battery indicator
Summer and winter setpoints
•Large back lit display
Adjustable temperature differential: .5°F to 3.0°F (0.5°C to 1.5°C)
Compressor short cycle protection
•Accuracy within ±1°
Zone system compatible as a master thermostat
Permanent memory retention
Fahrenheit/Celsius display option
Adjustable from 45°F to 90°F (7°C - 32°C)
Quick wire terminal block
Low temperature freeze protection. While in heat mode, thermostat
will mechanically turn on heat if temperature drops to 40°F (4°C)
even if batteries are missing or drained.
Automatic heating shutdown if temperature exceeds 94°F (34°C)
1
110-1039

Other manuals for Robertshaw 9400

Questions and Answers

  • R
    Rachel AdamsJul 31, 2025
    How to troubleshoot Robertshaw 9400 Thermostat that does not turn on?
    • S
      Sandra BridgesAug 1, 2025
      If your Robertshaw Thermostat does not turn on the system, check the wiring. Refer to the Installation section for wiring instructions.
  • S
    Sylvia RamirezAug 8, 2025
    What to do if my Robertshaw 9400 display is blank?
    • J
      Jason JensenAug 8, 2025
      If the display of your Robertshaw Thermostat is blank, flashing, or constantly showing 'LOW BATT,' the suggested solution is to replace the batteries.
  • D
    davidrodriguezAug 15, 2025
    Why does my Robertshaw 9400 turn on and off too frequently?
    • J
      Jill WyattAug 15, 2025
      If your Robertshaw Thermostat is turning the system on and off too frequently, the suggested solution is to increase the temperature differential. See the instructions on changing the temperature differential.
  • F
    fosteranitaAug 22, 2025
    What to do if system fan does not operate properly on Robertshaw 9400 Thermostat?
    • V
      Victoria BrayAug 22, 2025
      If the system fan is not operating properly with your Robertshaw Thermostat, move the fan option switch to either gas or electric to match your system. Refer to the installation instructions for guidance.

Summary

Important Safety Information

Step 1: Replacing Existing Thermostat

Step 2: Installing Model 9400 Thermostat

Wiring Diagrams

Terminal Legend - 9400

Step 3: Testing the Thermostat

Cooling System Test

Tests the thermostat's ability to control the cooling system, including the 5-minute compressor delay.

Heating System Test

Tests the thermostat's ability to control the heating system and display the flame icon.

Step 4: Customizing the Thermostat

Step 5: Troubleshooting

System Not Responding

Remedies for when the thermostat does not turn on the system.

Display Issues & Low Battery

Troubleshooting blank, flashing displays, or low battery warnings.

Robertshaw 9400 Specifications

General IconGeneral
DisplayDigital
BacklightYes
Hold FunctionYes
TypeProgrammable
PowerBattery-powered
CompatibilityConventional systems

Related product manuals