DLY2=SECOND STAGE DELAY = This timer starts when the first stage turns
on. It resets when the first stage turns off. If this timer runs out the
second stage will turn on (See Two Stage Systems).
DEDB = Deadband for auto changeover = the number of degrees that the
room temperature can move away from the active setpoint until
heating or cooling is called for. The larger the deadband the more
the room temperature will vary. This can be from heat to cool or cool
to heat.
HI = High Heat Limit = This is the highest allowed heating setpoint. The
user will not be allowed to set a schedule setpoint or override
temperature higher than this value.
LO = Low Cool Limit = This is the lowest allowed cooling setpoint. The
user will not be allowed to set a schedule setpoint or override
temperature lower than this value.
CHECK = Timer to remind the home owner to maintain the filter. Default
setting is off. The timer runs when the system is on. It can be set at
0 (OFF) or up to 9900 hours. When the time expires CHECK FLTR is
displayed. Press any button to reset and return to the normal display.
9

Other manuals for Robertshaw RS6220

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robertshaw RS6220 and is the answer not in the manual?

Robertshaw RS6220 Specifications

General IconGeneral
BrandRobertshaw
ModelRS6220
CategoryThermostat
LanguageEnglish

Related product manuals